Indicator Lights; Gas Valve - Dunkirk Q90 150 Installation Manual And Operating Instructions

Gas-fired direct vent condensing hot water boiler
Table of Contents

Advertisement

This section
provides
a brief description
of the key
controls
and accessories
found
in this boiler.
See Section
XVII, "Troubleshooting,"
in this instal-
lation
manual
for detailed
sequences
of operation
and troubleshooting
procedures.
See the separate-
ly provided
"Repair Parts Manual" for locations
of all
control components
and accessories
described.
The
Integrated
Boiler
Control
(IBC)
is a micro-
processor
based
controller
for high efficiency
gas
boilers
that monitors
all safety
controls
and which
controls
the operation
of the combustion
air blow-
er, circulator
pump, burner,
and a combination
hot
surface
igniter/flame
sensor.
This controller
is not
intended
for use with a vent damper. This controller
is mounted
on the control
panel
inside
the boiler
and contains
five diagnostic
indicator
lights.
The electronic
24 volt gas control valve contains
a
1:1 gas/air pressure
regulator
to control gas flow to
the main burner d the appliance,
is suited for both
natural and LP gas, and is rated in accordance
with
ANSI Z21.21 - latest revision and and CGA-6.5-M95.
GAS VALVE
VENTURI
VALVE
THROTTLE
/
J-
INLET
_
I/_
PRESSURE_
I
__
TAP
_
I
__AIR
PRESSURE
_]
_-x_,
_
CONNECTION
INLET
-- L_
_-
OUTLET
,o?xj
-T 52 A2E,OVE
HEADER
as a lack of flame signal. The IBC is manually
reset
from lockout by either removing
and reestablishing
the thermostat's
call for heat, or by turning the ser-
vice switch off, then back on.
iNDICATOR LIGHTS
f
-\
..................
INTEGRATED
BOILER
CONTROL
}
CONTROL
PANEL
IFiou olG]
The high limit aquastat
control determines
the maxi-
mum boiler water temperature
and also provides
a
means for protecting
the boiler and heating system
from unsafe operating
conditions
which could dam-
age the boiler. The aquastat is mounted in the ½" NPT
control well and 3A"x ½" bushing on the top of the front
boiler section at the hot water outlet. The aquastat is
tied in with the IBC and is factory set at 180°F water
temperature.
The high limit setpoint is field adjustable
and may be set anywhere between 100°F and 200°F.
The field setpoint adjustment
for each installation de-
pends on heating system requirements.
The aquastat
automatically
resets when the boiler water tempera-
ture drops 20°F below the setpoint value. This reset
value can be field adjusted within a range of 5-30°F.
NOTE:
The maximum
setpoint
of the aquastat
must
not_
xceed
2G0°F.
J
The 120 volt hot surface
igniter heats up to 1800°F
to initiate combustion
of the gas in the burner. The
igniter
is mounted
next to the burner
through
the
gas/air
mixer. The igniter
also serves
as a means
for proving the main burner flame by flame rectifica-
tion. In the event of a lack of flame signal on three
consecutive
trials for ignition,
the IBC will lock out.
The "Valve" and "Flame" diagnostic
indicator
lamps
(see Figure 16) will blink indicating
the failure mode
In the event of lack of or loss of water in the boiler,
the casting
temperature
safety switch
(230°F
set-
point)
installed
on the top of the aluminum
boiler
section
behind the supply piping shuts off the boiler
by shutting
off power
to the IBC and causes
the
power
indicator
light to go out. This fault requires
manual
reset
of the
casting
temperature
safety
switch
to restart
the boiler.
Verify
that the boiler
is properly
filled
with water
before
resetting
this
switch.