INSTRUCTION MANUAL TECNO R-EVOLUTION Line INDEX HOW TO USE THE MANUAL DESCRIPTION OF THE CENTRAL VACUUM CLEANER TECHNICAL DATA CONSTRUCTION CHARACTERISTICS SAFETY FEATURES AUTHORIZED USE OF THE VACUUM CLEANER UNAUTHORIZED USE OF THE VACUUM CLEANER EQUIPMENT AND ACCESSORIES INSTALLATION 18/03/13 Rev:2.0.0...
Page 4
INSTRUCTION MANUAL TECNO R-EVOLUTION Line INDEX 10 STARTING THE VACUUM CLEANER 11 USE OF THE VACUUM CLEANER 12 MAINTENANCE 18/03/13 Rev:2.0.0...
Page 5
INSTRUCTION MANUAL TECNO R-EVOLUTION Line INDEX 13 REPAIRS AND SPARE PARTS 14 SOUND EMISSION 15 IDEAL LOCATION OF THE UNIT TO REDUCE SOUND EMISSION 16 VIBRATIONS 17 TROUBLESHOOTING INTRODUCTION Please read the entire manual carefully, follow the instructions precisely, and above all, for safe- ty reasons, do not intervene in any way if not speci cally indicated.
TECNO R-evolution Instruction manual 1 - GENERAL INFORMATION 1. How to use the manual 2. DESCRIPTION OF THE VACUUM CLEANER TECNO REVOLUTION BI-VAC 18/03/13 Rev:2.0.0...
Page 7
Con guration 1 cyclonic (bagless) suction Con guration 2 bag suction con guration 2 with bag suction M-Class lter Tecno R-EVOLUTION Tecno R-EVOLUTION 18/03/13 Rev:2.0.0...
TECNO R-evolution Instruction manual 4 - CONSTRUCTION CHARACTERISTICS TECNO R-EVOLUTION Max. nr. Programmable Dust bag / Filtering Motor Max. Maximum Model Item Max. nr. Power supply suction computer bin capacity surface power air ow surface of users Volt ac inlets maintenance BiVac litres T.
Page 11
4.1 R-EVOLUTION kit mod. 150/250 with bag suction Cover Sound-absorbing dome Operator interface display control board Air venting Membrane keyboard Motor group Fixing plate Filter cartridge Cyclonic suction dust inlet Basic seal kit Aesthetic frame for elbow connector Cylinder motor body Dust bag Ring seal with gasket...
Page 12
TECNO R-evolution Instruction manual 4.2 R-EVOLUTION kit mod. 150/250 with cyclonic suction and service suction socket Cover Sound-absorbing dome Motor group Air venting Fixing plate Operator interface display Cyclonic suction control board dust inlet Membrane keyboard Basic seal kit Cylinder motor body Service suction socket...
Page 13
4.3 R-EVOLUTION kit mod.350/450 with bag suction 18/03/13 Rev:2.0.0...
Page 14
TECNO R-evolution Instruction manual 4.4 R-EVOLUTION kit mod.350/450 with cyclonic suction and service suction socket 18/03/13 Rev:2.0.0...
5 SAFETY FEATURES It is recommended to read carefully all the installation, use and maintenance instructions detailed in this manual. Do not vacuum any material which may cause electrostatic charges in the piping system, if not previously communicated to the constructor. 18/03/13 Rev:2.0.0...
Page 16
TECNO R-evolution Instruction manual WARNING: 5.1 IP Protection Degree 5.2 Electrical insulation degree 5.3 Declaration of absence of dangerous substances 5.4 Fixed closure guards safety 18/03/13 Rev:2.0.0...
TECNO R-evolution Instruction manual 6 - AUTHORIZED USE OF THE VACUUM CLEANER The vacuum cleaner can be installed in domestic dwellings with the following characteristics: 7 - UNAUTHORIZED USE OF THE VACUUM CLEANER It is extremely important NOT to use the system in the following circumstances which are conside- red to be inappropriate and dangerous: The system has not been designed to be used in environments with risk of explosion, and the- refore:...
8 - EQUIPMENT AND ACCESSORIES con guration 1 cyclonic suction with service suction socket: con guration 2 bag suction: To be used for the Components to be found in the kit Picture con guration N°4 18/03/13 Rev:2.0.0...
9 - INSTALLATION - WARNING - THESE PROCEDURES MUST BE CARRIED OUT BY QUALIFIED PERSONNEL 9.1 Preliminary operations 9.2 Place of installation 18/03/13 Rev:2.0.0...
Page 22
TECNO R-evolution Instruction manual 9.3 Transport and unpacking 18/03/13 Rev:2.0.0...
Page 23
9.4 Positioning of the vacuum cleaning unit 9.5 Transforming DX version (outlet pipes tted on the right) into SX version (outlet pipes tted on the left) 18/03/13 Rev:2.0.0...
Page 25
9.6 Fixing the vacuum cleaner to the wall Height from the ground is detailed in the table below: TECNO R-evolution Tecno Tecno Tecno Tecno R-evolution 150 R-evolution 250 R-evolution 350 R-evolution 450 Model Item 3110.2T 3112.2T 3113.2T 3115.2T X Size (min.) 18/03/13 Rev:2.0.0...
Page 26
TECNO R-evolution Instruction manual 9.7 Types of connection of dust collection couplings con guration 1 cyclonic bagless vacuum cleaning con guration 2 bag suction 18/03/13 Rev:2.0.0...
Page 27
9.7.1 Connection to the piping network (cyclonic suction see pages 10-12) 18/03/13 Rev:2.0.0...
Page 28
TECNO R-evolution Instruction manual 9.7.2 Connection to the piping network (bag suction see pages 9-11) 18/03/13 Rev:2.0.0...
9.7.3 Connection to the service suction socket (cyclonic suction) 10 STARTING THE VACUUM CLEANER 10.1 Control board 11). 18/03/13 Rev:2.0.0...
Page 30
TECNO R-evolution Instruction manual 10.2 Electrical connection WARNING: the electrical connection must be carried out ONLY by quali ed personnel. 18/03/13 Rev:2.0.0...
Page 31
10.2.1 Auxiliary connection signal 18/03/13 Rev:2.0.0...
TECNO R-evolution Instruction manual 11 USE OF THE VACUUM CLEANER R-EVOLUTION Tecno R-EVOLUTION 11.1 Switching on the vacuum cleaner 11.2 Using the vacuum cleaner 18/03/13 Rev:2.0.0...
Page 33
11.3 Programming and use of the computer for controlling the central unit 18/03/13 Rev:2.0.0...
Page 34
TECNO R-evolution Instruction manual 11.3.1 Programming the start up Screen display which appears when rst switching the system. LANGUAGE SELECTION English Italiano Deutsche Francais Espanol Selection is active Selection is not active MODEL Revolution 150 Revolution 250 Revolution 350 Revolution 450 Dual Power Selection is active Selection is not active...
Page 35
INFO INSTALLER * * * * * * * * * * INFO SERVICE * * * * * * * * * * DUST COLLECTION Selection is active Selection is not active 01/04/2013 10:00 Main Screen Display ENTER Main Suction: Depression: mbar 000...
Page 36
TECNO R-evolution Instruction manual Alarms Clean Empty Replace +390381650082 Motor overheating 11.3.2 Setting menu Enter 01/04/2013 10:00 Suction: Depression: mbar 000 Premere ENTER 18/03/13 Rev:2.0.0...
SETTINGS Enter Menu Setup 11.4 Menu MENU Timer dust container Enter Suction stop Maintenance Info Date/time 11.4.1 Menu timer of the dust container Down TIMER DUST CONTAINER 10 (h) 11.4.2 Menu suction stop CAUTION: Down SUCTION STOP ENTER Allarm Filter Allarm Dust Allarm Service 1 Allarm Service 2...
Page 38
TECNO R-evolution Instruction manual 11.4.3 Maintenance menu MAINTENANCE Filer ef cinecy %100 Dust level %000 Allarm Service 1 (h) 200 Allarm Service 2 (h) 400 11.4.4 Menu info Down INFO Enter Central unit Installer Service Last alarms Statistics Alarms Statistics Service Down INFO CENTRAL UNIT Installation date...
Page 39
INFO INSTALLER * * * * * * * * * * INFO SERVICE * * * * * * * * * * Installer: Service: LAST ALARMS 01/04/2013: Alarm lter 01/07/2013: Alarm Dust Down 01/10/2013: Alarm Service 1 01/10/2014: Alarm Service 2 01/10/2014: Alarm Motor...
Page 40
TECNO R-evolution Instruction manual 11.4.5 Menu date and time DATE/TIME Down Left Right 01/01/2013 12:00 11.5 Setup SETUP Down Start/Stop Enter Dust collection Parameters Language Model Selection is active Selection is not active 11.5.1 Setup start/stop SETUP Enter Start/Stop Dust collection Parameters Language Selection is active...
Page 41
11.5.2 Set up dust collection DUST COLLECTION Right Left Selection is active Selection is not active 11.5.3 Set up parameters CAUTION: PARAMETERS Alarm bag 1 <164> mbar Alarm bag 2 <180> mbar Alarm bag 3 <190> mbar PARAMETERS Down Alarm lter 1 <085>...
Page 42
TECNO R-evolution Instruction manual PARAMETERS Down Display stand by Left Right <005> min PARAMETER REFERENCE Set point depression alarm dust container (bag) Alarm bag 1 Revolution 150/250 Set point depression alarm dust container (bag) Alarm bag 2 Revolution 350 Set point depression alarm dust container (bag) Alarm bag 3 Revolution 450 Set point depression alarm...
Page 43
11.5.4 Set up reset parameters ENTER RESET PARAMETERS Reset parameters Selection is active Selection is not active 11.5.5 Set up language Down LANGUAGE SELECTION Enter English Italiano Deutsche Francais Selection is active Espanol Selection is not active 11.5.6 6 Set up unit model Down MODEL Enter...
Page 44
TECNO R-evolution Instruction manual 12 - MAINTENANCE BEFORE CARRYING OUT ANY MAINTENANCE OPERATION, IT IS MANDATORY TO UNPLUG THE POWER SUPPLY CABLE FROM THE POWER SUPPLY SOCKET. PROTECTIVE MASK AND GLOVES MUST ABSOLUTELY BE WORN 12.1 Programmed routine maintenance 12.2 Extraordinary maintenance 18/03/13 Rev:2.0.0...
Page 45
12.3 Cleaning the suction container (cylinder) Important: only use water or neutral soap and water to clean the vacuum cleaner. The use of other solvents or alcohol can entail damages. Ensure the system surface is completely dry before switching it back on. 12.4 Emptying the dust bin (cyclonic suction) 18/03/13 Rev:2.0.0...
Page 46
TECNO R-evolution Instruction manual Remember to take care when emptying the bin: if there is a huge quantity of dust, make sure you do not throw away the conveyor cone. Always check that the conveyor cone is still in place and correctly assembled in its housing inside the bin.
Page 47
12.6 Dust collection, transfer and disposal 12.7 Disposal of the lter cartridge ATTENTION YOU SHALL ALWAYS CHECK THE RIGHT POSITIONING AND TIGHTENING OF THE FILTER CARTRIDGE. A WRONG POSITIO- NING OR A LOOSE FILTER CARTRIDGE MAY CAUSE A SERIOUS DAMAGE OF THE PRODUCT. DO NOT USE THE VACUUM CLEANER WITHOUT THE FILTER CARTRIDGE.
TECNO R-evolution Instruction manual 13 - REPAIRS AND SPARE PARTS 13.1 Intervention criteria 13.2 Recommended spare parts SPARE VACUUM DESCRIPTION PART CLEANER CODE MODEL 1610.0R 1614.5 1614.4 13.3 Putting the suction system out of service 14 - SOUND EMISSION 15 - IDEAL LOCATION OF THE VACUUM CLEANER TO REDUCE SOUND EMISSION 16 - VIBRATIONS 18/03/13 Rev:2.0.0...
17 - TROUBLE SHOOTING PROBLEM CAUSE SOLUTION Alarm signalled on the display Carry out alarm RESET The power cable is unplugged Connect the power cable The start button is on OFF Press the Start button position The micro line cable is not Connect the activation cable connected (sensor)
Page 50
TECNO R-evolution Instruction manual PROBLEM CAUSE SOLUTION RESET the alarm and/or wait for the automatic restoration Check for a possible clogging in the piping network Check for a possible clogging in Alarm “Thermal switch” on the the air discharge pipe display.
Need help?
Do you have a question about the Tecno R-evolution 150 and is the answer not in the manual?
Questions and answers