Fire alarm city connect card and dact module

Advertisement

Cautions and Warnings

Overview

In This Publication
1999 Simplex Time Recorder Co., Gardner, MA 01441-0001 USA
All specifications and other information shown were current as of publication, and are subject to change without notice.
Technical Manuals Online! - http://www.tech-man.com
City Connect Card and DACT Module
DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS
DAMAGED. Upon unpacking your Simplex product, inspect the contents of
the carton for shipping damage. If damage is apparent, immediately file a claim
with the carrier and notify Simplex.
ELECTRICAL HAZARD - Disconnect electrical power when making any
internal adjustments or repairs. Servicing should be performed by qualified
Simplex Representatives.
STATIC HAZARD - Static electricity can damage components. Therefore,
handle as follows:
1.
Ground yourself before opening or installing components (use the 553-484
Static Control Kit).
2.
Keep uninstalled components wrapped in anti-static material at all times.
RADIO FREQUENCY ENERGY - This equipment generates, uses, and can
radiate radio frequency energy and if not installed and used in accordance with
the instruction manual, may cause interference to radio communications. It has
been tested and found to comply with the limits for a Class A computing device
pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area may cause
interference in which case the user at his own expense will be required to take
whatever measures may be required to correct the interference.
The 4004 Fire Alarm System is capable of supporting either one City Connect
Card (565-577, 565-999, or 566-078) or one DACT module. This publication
covers the procedure for installing a city connect card into a 4004 Panel. It also
covers the procedure for re-installing a 2080-9044 DACT into a 4004 Panel for
existing jobs.
For new DACT installations use the 4004-9810 DACT (565-626). Refer to the
Contact Closure DACT (Digital Alarm Communication Transmitter) Installation
Programming Instructions (574-049) for more information on the 4004-9810
DACT.
The following topics are covered in this publication:
Topic
Overview
City Connect Card Installation
DACT Module Installation

4004 Fire Alarm

Installation Instructions

See Page #
1
2
4
574-077
Rev. B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4004 and is the answer not in the manual?

Questions and answers

Summary of Contents for Simplex 4004

  • Page 1: Fire Alarm

    The 4004 Fire Alarm System is capable of supporting either one City Connect Card (565-577, 565-999, or 566-078) or one DACT module. This publication covers the procedure for installing a city connect card into a 4004 Panel. It also covers the procedure for re-installing a 2080-9044 DACT into a 4004 Panel for existing jobs.
  • Page 2 City Connect Card Installation Introduction For all wiring information, use the 4004 Field Wiring Diagram (841-992). Also reference the Contractor Wiring Termination Label (519-698) inside the 4004 Door Panel. The label shows the following information: • The installation location of the city connect card.
  • Page 3 (SW1 and SW2); the normal position for both switches is the active “ON” position. City Connect Card (566-078) does not have these switches. Power-up and Configuration Power-up the 4004 System and configure the city connect card using the programming instructions located on the Termination Wiring Label (519-698) inside the door.
  • Page 4 DACT module. For all wiring information, use the Field Wiring Diagram (841-992). DACT modules mount to the 4004 Back Box in a physical location where the DACT status LEDs can be viewed from a cutout slot opening on the mounting plate.
  • Page 5 Cut and strip the green Earth connect wire on the DACT module and (Continued) connect to the 4004 Back Box using an 18 AWG green wire and wire nut. Isolate the circuit ground connection from P1-1 of DACT. The ground return is provided through Wiring Harness (733-897, supplied).
  • Page 6 Connect Wiring Harness (733-897, supplied) from System Board P5 to (Continued) DACT module P2, P5, and TB1. 10. Power-up and configure the 4004 System for the DACT module using the programming instructions located on the Contractor Wiring Termination Label (519-698) on the door.