Troubleshooting - Motorola X-Pad Owner's Manual

Handheld data terminal
Table of Contents

Advertisement

It is the responsibility of the user to use only the approved accessories
supplied for this product, as detailed in Table 3 . Motorola is not responsi-
ble for the use of accessories not approved for this product.
For more information on the availability of these accessories, please call
your company supplier.

Troubleshooting

Problem
X-Pad does not
turn On
Battery does not
charge in UOD
18
Table 4: Troubleshooting the X-Pad
Cause
Battery is not
installed properly or
not charged
X-Pad in Suspend
mode
X-Pad is not locked in
UOD
X-Pad or UOD Dock
contacts are not clean
Battery temperature
is out of range
Bad battery
Solution
Ensure proper battery installa-
tion in X-Pad.
Charge or replace the battery
Press the Power Button
Reinstall X-Pad in UOD. Lock the
X-Pad properly in UOD. (See that
the UOD LED is On and charge
for three hours)
Clean contacts and remove dust
and objects from within the UOD
Ensure that the battery tempera-
ture range is 32°F to 95°F (0°C
to 35°C)
Replace battery

Advertisement