B&B Electronics Elinx EIR510-2MC-T User Manual

Ten port managed industrial ethernet switches
Table of Contents

Advertisement

Quick Links

Product Description

Model EIR510-2xx-T
Documentation Number: EIR510-2xx-T_0708m
707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA
Phone (815) 433-5100 -- General Fax (815) 433-5105
Phone (815) 433-5100 -- General Fax (815) 433-5105
Website:
www.bb-elec.com
Sales e-mail:
orders@bb-elec.com
-- Fax (815) 433-5109
Technical Support e-mail:
support@bb.elec.com
-- Fax (815) 433-5104
European Headquarters
B&B Electronics
Westlink Commercial Park -- Oranmore, Co. Galway, Ireland
Phone +353 91-792444 -- Fax +353 91-792445
Website:
www.bb-europe.com
Sales e-mail:
sales@bb-europe.com
Technical Support e-mail:
support@bb-europe.com
© 2008 B&B Electronics Mfg. Co. Inc. - Revised February 2008
Manual Documentation Number: EIR510-2xx-T-0708m
1
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Elinx EIR510-2MC-T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for B&B Electronics Elinx EIR510-2MC-T

  • Page 1: Product Description

    Product Description Model EIR510-2xx-T Documentation Number: EIR510-2xx-T_0708m 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Phone (815) 433-5100 -- General Fax (815) 433-5105 Website: www.bb-elec.com Sales e-mail: orders@bb-elec.com -- Fax (815) 433-5109 Technical Support e-mail: support@bb.elec.com...
  • Page 2: User Manual

    Ten Port Managed Industrial Ethernet Switches User Manual B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 3 This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
  • Page 4: Table Of Contents

    Content Introduction ... 1 Features ... 1 Package Contents ... 3 Hardware Description ... 4 Physical Dimension (W x D x H) ... 4 Front Panel ... 4 Bottom View ... 5 LED Indicators ... 6 Ports ... 7 Cabling ... 9 Wiring the Power Inputs ...
  • Page 5 X-Ring Application ... 16 Coupling Ring Application ... 17 Dual Homing Application ... 18 Console Management ... 19 Connecting to the Console Port ... 19 Login in the Console Interface ... 19 CLI Management ... 20 Commands Level ... 21 Commands Set List ...
  • Page 6 TFTP – Restore Configuration ... 52 TFTP - Backup Configuration ... 52 System Event Log – Syslog Configuration ... 53 System Event Log - SMTP Configuration ... 54 System Event Log - Event Configuration ... 55 Fault Relay Alarm ... 56 SNTP Configuration ...
  • Page 7 Rapid Spanning Tree ... 73 RSTP System Configuration... 73 RSTP Port Configuration ... 75 SNMP Configuration ... 76 System Configuration ... 76 Trap Configuration ... 77 SNMPV3 Configuration ... 78 QoS Configuration ... 81 QoS Policy and Priority Type ... 81 Port Base Priority ...
  • Page 8: Technical Specification

    Technical Specification ... 95   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 9: Introduction

    Introduction This managed industrial switch is a cost-effective solution and meets the high reliability requirements demanded by industrial applications. The 8 10/100TX plus 2 100FX managed industrial switch can be easily managed through a Web GUI. The fiber ports extend the connection distance, increasing network elasticity and performance.
  • Page 10 Security Port Security : MAC address entries/filter IP Security : IP address security management Login Security: IEEE802.1X/RADIUS IGMP with Query mode for Multi Media Application Case/Installation IP-30 Protection DIN Rail and Panel Mount Design Spanning Tree IEEE802.1d Spanning Tree IEEE802.1w Rapid Spanning Tree X-ring X-ring, Dual Homing, and Couple Ring Topology Redundant backup feature with recovery time below 300ms...
  • Page 11: Package Contents

    One CD ROM containing a user manual RS-232/RJ-45 cable 2 panel mount plates with 6 screws One DIN-Rail Clip (attached on the switch) If any items are missing, contact B&B Electronics for a replacement. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com...
  • Page 12: Hardware Description

    2.9 x 4.2 x 6.4 in (7.4 x 10.7 x 16.3 cm) Front Panel Front Panel of the industrial switch Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com...
  • Page 13: Bottom View

    Bottom View Bottom Panel of the industrial switch Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 14: Led Indicators

    Orange setting for operational details) Normal Operation The switch is the master of an Green X-Ring group The switch is not the master of an X-Ring group Green Fiber port linked Blinks Fiber port transmitting or receiving No device attached...
  • Page 15: Ports

    Ports RJ-45 ports There are 8x 10/100Mbps auto-sensing ports with MDI/MDIX. The switch can connect to another switch or workstation without changing between straight through or crossover cabling. Pin Number Straight Through Cable Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 16: Fiber Port

    Fiber Port There are two 100Base-FX ports. The fiber port is SC or ST type connectors in multi mode (2Km) or single mode (30Km). Connect the fiber ports as shown below (Transmit to distant end receive and vice versa). ATTENTION This is a Class 1 Laser/LED product.
  • Page 17: Cabling

    Cabling Use Category 5 cabling for RJ-45 port connection. The cable between the switch and the network device (switch, hub, workstation, etc.) must be less than 328 feet (100 meters) long. Single-mode fiber ports must use 9/125 um single-mode fiber cable.
  • Page 18: Wiring The Power Inputs

    Wiring the Power Inputs V- V+ V- V+ 1. Insert the positive and negative wires into the V+ and V- contacts on the terminal block connector. 2. To tighten the wire-clamp screws. [NOTE] Use 12 to 24 AWG wire. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc –...
  • Page 19: Wiring The Fault Alarm Contact

    Wiring the Fault Alarm Contact 1A@24V Insert the wires into the fault alarm contact [NOTE] Use 12 to 24 AWG wire. [NOTE] Relay contacts are normally open. [NOTE] The Relay Alarm also requires software configuration. Refer to the Web Based Management Fault Relay Alarm Section. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc –...
  • Page 20: Mounting Installation

    Mounting Installation DIN-Rail Mounting 1. Use the screws to attach the DIN-Rail to the switch Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 21 Lightly push the DIN-Rail into the track. Ensure the DIN-Rail is tightly on the track. To remove the industrial switch from the track, reverse steps above. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com...
  • Page 22: Panel Mounting

    2. Place the panel mount plate on the rear panel of the industrial switch. 3. Use the screws to attach the panel mount plate. 4. Use the hook holes at the corners to attach the switch to the panel. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc –...
  • Page 23: Hardware Installation

    Hardware Installation Installation Steps 1. Unpack the switch 2. Attach the switch to the DIN-Rail or panel. 3. Apply power to the switch. 4. Connect the switch to the network devices. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com...
  • Page 24: Network Application

    Network Application X-Ring Application This switch incorporates the X-Ring Protocol to ensure network reliability and system restoration within 300 ms in the event of a connection failure. The X-Ring algorithm is similar to the spanning tree protocol (STP) algorithm but it has faster recovery time. The following figure below is an example of an X-Ring application.
  • Page 25: Coupling Ring Application

    Coupling Ring Application If the network has more than one X-Ring group, the coupling ring function is used to connect them and add redundancy. This ensures that transmissions between the two ring groups will not fail. The figure below is an example of the coupling ring application.
  • Page 26: Dual Homing Application

    The Dual Homing function is used to prevent a connection loss between the X-Ring group and the upper level/core switch. Assign a port in each X-ring group to be the Dual Homing ports The Dual Homing function can only be used when the X-Ring function is active.
  • Page 27: Console Management

    The PC must have support a terminal emulation program. Login in the Console Interface When the connection between Switch and PC is ready, turn on the PC, run a terminal emulation program or Hyper Terminal, and configure the following communication parameters:...
  • Page 28: Cli Management

    The settings of communication parameters After entering the parameters, click ‘OK’. When the blank screen shows up, press Enter on the PC keyboard. A login screen will be displayed. Enter ‘root’ for the User name and Password. CLI Management After you login to the system, you will see a command prompt. To enter CLI management interface, type ‘enable’...
  • Page 29: Commands Level

    Commands Level Access Modes Method Begin a User EXEC session with your switch. Enter the enable Privileged command EXEC while in user EXEC mode. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 30: Commands Set List

    To exit to Use this mode to privileged switch configure parameters EXEC (config)# that apply to your mode, enter switch as a whole. exit or end To exit to Use this mode to switch user EXEC configure (vlan)# mode, enter VLAN-specific exit.
  • Page 31 Show console switch#show terminal information Save user switch#write memory configuration into permanent memory (flash rom) Configure system switch(config)#system name xxx name Set switch system switch(config)#system location location string Set switch system switch(config)#system description string description xxx Set switch system...
  • Page 32 (maximum 10 words) Specifies a password switch(config)#admin password (maximum 10 words) xxxxxx Show administrator switch#show admin information Enable DHCP Server switch(config)#dhcpserver enable Disable DHCP Server switch(config)#no dhcpserver Configure low IP switch(config)#dhcpserver lowip address for IP pool 192.168.1.100 Configure high IP switch(config)#dhcpserver highip address for IP pool 192.168.1.200...
  • Page 33 Enable IP security of switch(config)#security http HTTP server Enable IP security of switch(config)#security telnet telnet server Set the IP security list switch(config)#security ip 1 192.168.1.55 Show the information switch#show security of IP security Disable IP security switch(config)#no security function...
  • Page 34 Set interface ingress switch(config)#interface limit frame type to fastEthernet 2 “only accept broadcast switch(config-if)#bandwidth type frame” broadcast-only Set interface input switch(config)#interface bandwidth. Rate fastEthernet 2 Range is from 100 switch(config-if)#bandwidth in 100 kbps to 102400 kbps or to 256000 kbps for...
  • Page 35 Set interface output switch(config)#interface bandwidth. Rate fastEthernet 2 Range is from 100 switch(config-if)#bandwidth out kbps to 102400 kbps or to 256000 kbps for giga ports, and zero means no limit. Show interfaces switch(config)#interface...
  • Page 36 B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com Clear interface switch(config)#interface accounting information fastEthernet 2 switch(config-if)#no accounting Example Set port group system switch(config)#aggregator priority priority Set activity port...
  • Page 37: Vlan Commands Set

    1 of trunk group switch#show aggregator 2 switch#show aggregator 3 Disable the LACP switch(config)#no aggreator lacp function of trunk group Remove a trunk group switch(config)#no aggreator group 2 Example Enter VLAN configure switch#vlan database mode To set switch VLAN switch(vlan)#vlanmode portbase mode.
  • Page 38 VLAN by trunk access-link untag 33 group Assign a trunk link for switch(vlan)#vlan 8021q trunk 3 VLAN by trunk group trunk-link tag 2,3,6,99 switch(vlan)#vlan 8021q trunk 3 trunk-link tag 3-20 Assign a hybrid link for switch(vlan)#vlan 8021q trunk 3...
  • Page 39: Spanning Tree Commands Set

    15 configuration command to change the interval between messages the spanning tree receives from the root switch. If a switch does not receive a bridge protocol data unit (BPDU) message from the root switch within this interval, it...
  • Page 40 Use the spanning-tree switch(config)#interface cost interface fastEthernet 2 configuration switch(config-if)#stp-path-cost 20 command to set the path cost for Spanning Tree Protocol (STP) calculations. In the event of a loop, spanning tree...
  • Page 41 Admin NonSTP of STP switch(config)#interface priority on this fastEthernet 2 interface. switch(config-if)#stp-admin-non-s tp False Displays a summary of switch>show spanning-tree the spanning-tree states. Disable spanning-tree. switch(config)#no spanning-tree Example Select QOS policy switch(config)#qos policy scheduling weighted-fair Setting of QOS priority switch(config)#qos prioritytype...
  • Page 42 B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com type Configure Port-based switch(config)#qos priority Priority portbased 1 low Configure COS Priority switch(config)#qos priority cos 0 middle Configure TOS Priority switch(config)#qos priority tos 3 high Switch#show qos Displays the...
  • Page 43 2 interface (static). switch(config-if)#mac-address-tab le static hwaddr 000012345678 Configure MAC switch(config)#mac-address-table address table(filter) filter hwaddr 000012348678 Show all MAC address switch#show mac-address-table table Show static MAC switch#show mac-address-table address table static Show filter MAC switch#show mac-address-table address table. filter...
  • Page 44 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com system contact system-contact where Select the agent mode switch(config)#snmp agent-mode of SNMP v1v2cv3 Add SNMP community switch(config)#snmp string.
  • Page 45 Remove the specified switch(config)#no snmp community. community-strings public Remove the SNMP switch(config)#no snmp-server server host. 192.168.1.50 Remove specified user switch(config)#no snmpv3 user of SNMPv3 agent. Test Remove specified switch(config)#no snmpv3 access access table of context-name Test group G1 SNMPv3 agent. security-level AuthPr...
  • Page 46 Show port monitor switch(config)#interface information fastEthernet 2 switch(config-if)#show monitor Disable source port of switch(config)#interface monitor function fastEthernet 2 switch(config-if)#no monitor Example Use the 802.1x global switch(config)# 8021x enable configuration command to enable 802.1x protocols. Use the 802.1x system switch(config)# 8021x system...
  • Page 47 B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com radious IP global radiousip 192.168.1.1 configuration command to change the radious server IP. Use the 802.1x system switch(config)# 8021x system server port global serverport 1815 configuration command to change the radious server port Use the 802.1x system...
  • Page 48 B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com command to set the TX period. Use the 802.1x misc switch(config)# 8021x misc supp timeout global supportimeout 20 configuration command to set the supplicant timeout.
  • Page 49 Example Set System log server switch(config)# systemlog ip IP address. 192.168.1.100 Specified the log mode switch(config)# systemlog mode both Displays system log. Switch>show systemlog Show system log client switch#show systemlog & server information...
  • Page 50 Configure Rcpt e-mail switch(config)#smtp rcptemail 1 Address Alert@test.com Show the information switch#show smtp of SMTP Disable SMTP function switch(config)#no smtp Set cold start event switch(config)#event type device-cold-start both Set Authentication switch(config)#event failure event type authentication-failure both Set X-ring topology...
  • Page 51 SMTP fastethernet 3 switch(config-if)#no event smtp Show system log client switch#show systemlog & server information Example Enable SNTP function switch(config)#sntp enable Enable daylight saving switch(config)#sntp daylight time, if SNTP function is inactive, this command can’t be applied. Set period of daylight...
  • Page 52 Enable dual homing switch(config)#Xring dualhoming Configure 1st/2nd switch(config)#Xring ringport 7 8 Ring Port Configure Coupling switch(config)#Xring couplingport Port Configure Control Port switch(config)#Xring controlport 2 Configure Dual switch(config)#Xring homingport Homing Port Show the information switch#show Xring of X - Ring...
  • Page 53 B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com Disable X-ring switch(config)#no X ring Disable ring master switch(config)# no Xring master Disable couple ring switch(config)# no Xring couplering Disable dual homing...
  • Page 54: Web-Based Management

    Preparing for Web Management Before using web management, install the industrial switch on the network and verify that a PC on the local network can connect with the switch through the web browser. The default IP Address, Subnet Mask, Username and Password is listed below: IP Address: 192.168.16.1...
  • Page 55: System Login

    System Login Launch Internet Explorer on the PC Enter “http:// “+” the IP address of the switch”, and then Press “Enter”. The login screen will appear Enter user name and password. The default user name and password are “root” Press “Enter” or ”OK”...
  • Page 56: System Information

    System Information System Name: A name (64 bytes max) can be assigned to the switch. System Description: Displays the description of switch. Read only cannot be modified System Location: A physical location (64 bytes max) can be assigned to the switch.
  • Page 57: Dhcp Server - System Configuration

    IP configuration interface DHCP Server – System configuration The switch can function as a DHCP server. DHCP Server: Enable or Disable the DHCP Server function. Low IP Address: the dynamic IP assign range. Low IP address is the beginning of the dynamic IP assignment range.
  • Page 58: Dhcp Client - System Configuration

    DHCP Server Configuration interface DHCP Client – System Configuration DHCP client information is displayed. DHCP Client Entries interface DHCP Server - Port and IP Bindings You can assign a specific IP address that is in the dynamic IP assignment range to the specific port. When the device is connected to the port and asks for an assignment, the system will assign this IP address.
  • Page 59: Tftp - Update Firmware

    Port and IP Bindings interface TFTP - Update Firmware Provides the ability to update the switch’s firmware. Before updating, ensure you the TFTP server is ready and the firmware image is on the TFTP server. TFTP Server IP Address: Enter the TFTP server IP.
  • Page 60: Tftp - Restore Configuration

    TFTP – Restore Configuration If the EEPROM image is stored on the TFTP server, you can restore it to flash memory. TFTP Server IP Address: Enter the TFTP server IP. Restore File Name: Enter the restore file name. Click Apply Restore Configuration interface TFTP - Backup Configuration You can save current EEPROM image to the TFTP server.
  • Page 61: System Event Log - Syslog Configuration

    System Event Log – Syslog Configuration Syslog Client Mode: select the system log mode – client only, server only, or both S/C. System Log Server IP Address: Assign the system log server IP. Click Reload to refresh the event log. Click Clear to clear all current event log.
  • Page 62: System Event Log - Smtp Configuration

    B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com johnadmin for the switch.
  • Page 63: System Event Log - Event Configuration

    System Event Log - Event Configuration When the selected events occur, the system will generate a log entry and email notification message. System event selection: Four selections available – Cold Start, Warm Start, SNMP Authentication Failure, and X-ring topology change. Mark the checkbox to select the event.
  • Page 64: Fault Relay Alarm

    Event Configuration interface Fault Relay Alarm Power Failure: When the check box is marked, the Fault LED will light if the power source fails. Port Link Down/Broken: When the check box is marked, the Fault LED will light if a port link goes down. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc –...
  • Page 65: Sntp Configuration

    SNTP Configuration SNTP allows you to synchronize switch clocks. SNTP Client: Enables or disables the SNTP function Daylight Saving Time: Enables or disables daylight saving time. When this function is enabled, the time period must be entered. UTC Time zone: Sets the local time zone.
  • Page 66 EDT - Eastern Daylight EST - Eastern Standard CDT - Central Daylight CST - Central Standard MDT - Mountain Daylight MST - Mountain Standard PDT - Pacific Daylight PST - Pacific Standard ADT - Alaskan Daylight ALA - Alaskan Standard HAW - Hawaiian Standard Nome, Alaska...
  • Page 67 SNTP Sever URL: Enter the SNTP server IP address. Daylight Saving Period: Enter the Daylight Saving beginning time and Daylight Saving end time. Daylight Saving Offset (mins): Enter the offset in minutes. Switch Timer: Displays the current time. Apply Click SNTP Configuration interface Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc –...
  • Page 68: Ip Security

    Security IP 1 ~ 10: Enter up to 10 IP addresses. And then, click Apply [NOTE] If the configuration is not saved, it will be lost when the switch is powered down. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 69: User Authentication

    User Authentication Use this function to change the login name and password. User name: Enter the new user name (The default is ‘root’). Password: Enter the new password (The default is ‘root’). Confirm password: Confirm the new password. And then, click Apply User Authentication interface Port Statistics...
  • Page 70: Port Control

    Port Control Used to configure and view port settings. Port: Select the port to configure. State: Enable or disable the port. Negotiation: Set the negotiation status of the port. Speed: Set the port link speed. Duplex: Set the port to full or half-duplex. Flow Control: Set flow control to Symmetric or Asymmetric in Full Duplex mode.
  • Page 71: Port Trunk

    This feature expands bandwidth to a device on the network. LACP operation requires full-duplex mode. Aggregator setting System Priority: a value used to identify the active LACP. The switch with the lowest value has the highest priority. It is selected as the active LACP.
  • Page 72 Group ID: There are three trunk groups to configure. Choose the "Group ID" and click LACP: If enabled, the group is an LACP static trunk group. If disabled, the group is local static trunk group. All ports support LACP dynamic trunk.
  • Page 73: Aggregator Information

    Port Trunk—Aggregator Setting interface Aggregator Information Displays static trunk group information. Port Trunk – Aggregator Information interface State Activity When you had setup the LACP aggregator, port state activity can be configured. Mark port click Active or Passive depending on its previous state. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc –...
  • Page 74: Port Mirroring

    Active: The port automatically sends LACP protocol packets. Passive: The port responds only if it receives LACP protocol packets from the opposite device. [NOTE] 1. A link having either two active LACP ports or one active port can perform dynamic LACP trunk. 2.
  • Page 75: Rate Limiting

    Port Trunk – Port Mirroring interface Rate Limiting Set up each port’s bandwidth rate and frame limitation type. Ingress Limit Frame type: Select the frame type to filter. There are four options: All, Broadcast/Multicast/Flooded Unicast, Broadcast/Multicast and Broadcast only. Egress Limit: The egress rate limit is ALL. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc –...
  • Page 76: Vlan Configuration

    VLAN configuration A Virtual LAN (VLAN) can be thought of as a broadcast domain that exists within a switch or a defined set of switches. By grouping switch ports into VLANs, traffic flooding is limited since devices can only communicate directly with devices belonging to the VLAN.
  • Page 77: Vlan Configuration - Port-Based Vlan

    VLAN Configuration interface VLAN configuration - Port-based VLAN With port-based VLAN, the port is assigned to a VLAN. Therefore, all devices attached to a given port should be members of the same VLAN. As with other VLAN configurations, the packets forwarded using this method do not leak into other VLAN domains on the network.
  • Page 78 VLAN. button to modify an existing VLAN group. Edit [NOTE] If the configuration is not saved, it will be lost when the switch is powered down. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com...
  • Page 79: 802.1Q Vlan

    “tag” into the Ethernet frame. The tag contains a VLAN Identifier (VID). When the 802.1Q VLAN is enabled, all ports on the switch belong to a default VLAN (VID 1). The default VLAN cannot be deleted. Up to 64 VLAN groups are supported.
  • Page 80: Group Configuration

    Access Link: Single switch only. Allows ports to be grouped by setting the same VID. Trunk Link: Extended application of Access Link. Allows ports to be grouped by setting the same VID on two or more switches. Hybrid Link: Both Access Link and Trunk Link.
  • Page 81: Rapid Spanning Tree

    The Rapid Spanning Tree Protocol (RSTP) is an evolution of Spanning Tree Protocol (STP). It provides a faster spanning tree convergence after a topology change. The switch will auto detect a device that is running STP or RSTP protocol. RSTP System Configuration RSTP state can be modified.
  • Page 82 2 x (Forward Delay Time value –1) > = Max Age value >= 2 x (Hello Time value +1) 2. If the configuration is not saved, it will be lost when the switch is powered down. RSTP System Configuration interface Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc –...
  • Page 83: Rstp Port Configuration

    RSTP Port Configuration Configure path cost and priority of each port. 1. Select the port in Port column. 1. Path Cost: The cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number 1 through 200000000. 2.
  • Page 84: Snmp Configuration

    SNMP Configuration Simple Network Management Protocol (SNMP) is the protocol developed to manage nodes (servers, workstations, routers, switches, hubs, etc.) on an IP network. SNMP enables network administrators to manage network performance, find and solve network problems, and plan for network growth. Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP System Configuration...
  • Page 85: Trap Configuration

    A trap manager is a management station that receives traps (the system alerts generated by the switch). If the trap manager is not defined, traps will not be issued. Create a trap manager by entering the IP address of the station and a community string.
  • Page 86: Snmpv3 Configuration

    SNMPV3 Configuration Configure the SNMP V3 function. Context Table Configure SNMP v3 context table. Assign the context name of context table. Click to add context name. Click context name. User Profile Configure SNMP v3 user table. User ID: Enter user name. Authentication Password: Enter the password.
  • Page 87 SNMP V3 configuration interface Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 88 Group Table Configure SNMP v3 group table. Security Name (User ID): assign the user name that was set up in user table. Group Name: Enter the group name. Click Click to remove unwanted context name. Remove Access Table Configure SNMP v3 access table. Context Prefix: set up the context name.
  • Page 89: Qos Configuration

    QoS Policy and Priority Type QoS Policy: select the QoS policy rule. Use an 8,4,2,1 weighted fair queuing scheme: The switch will follow 8:4:2:1 rate to process the priority queue from the highest to the lowest queue. For example, when processing, 1 frame of the...
  • Page 90 QoS Configuration interface Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 91: Port Base Priority

    Port Base Priority Configure per port priority level. Port 1 through 10: 4 priority levels – High, Middle, Low, and Lowest. Click Apply COS Configuration Set up the COS priority level. COS priority: Set up the COS priority level 0~7 –High, Middle, Low, Lowest.
  • Page 92: Igmp Configuration

    Group The switch support IP multicast, you can enable IGMP protocol on web management’s switch setting advanced page, then the IGMP snooping information displays. IP multicast addresses range are from 224.0.0.0 through 239.255.255.255.
  • Page 93: X-Ring

    The switch can be set in the ring master or slave mode. The ring master negotiates and places commands to the other switches in the X-Ring group.
  • Page 94 Control port: Set the switch as the master switch in the coupling ring. Enable Dual Homing: Set up one of port on the switch to be the Dual Homing port. In an X-Ring group, only one port can be the Dual Homing port.
  • Page 95: 802.1X/Radius Configuration

    [NOTE] 1. When X-Ring function is enabled, disable the RSTP function. X-Ring and RSTP cannot exist at the same time. 2. If the configuration is not saved, it will be lost when the switch is powered down. Security In this section, you can configure 802.1x and MAC address table.
  • Page 96: X Per Port Configuration

    802.1x System Configuration interface 802.1x Per Port Configuration You can configure 802.1x authentication state for each port. The State choices are Disable, Accept, Reject and Authorize. Use the ‘Space’ key change the state value. Reject: The port is held in the unauthorized state. Accept: The port is held in the Authorized state.
  • Page 97: Misc Configuration

    Supplicant Timeout: Sets the period the switch waits for a supplicant response to an EAP request. Server Timeout: Set the period the switch waits for a server response to an authentication request. Max Requests: Sets the number of authentications that time-out before authentication fails and the authentication session ends.
  • Page 98: Mac Address Table

    MAC Address Table Static MAC Address You can add a static MAC address. This address remains in the switch's address table, regardless of whether the device is physically connected to the switch. Therefore, the switch does not have to re-learn a device's MAC address when the disconnected or powered-off device reconnects to the network.
  • Page 99: Mac Filtering

    Static MAC Addresses interface MAC Filtering MAC Filtering interface MAC Address: Enter the MAC address that you want to filter. Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 100: Factory Default

    All MAC Address interface Factory Default To reset switch to default configuration, with an option to retain the current IP address and user name/password click Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 101: Save Configuration

    Save Configuration Save configuration changes click System Reboot Reboot the switch click Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 102: Trouble Shooting

    Trouble shooting Verify that 24 to 48VDC power is available. Do not exceed 48VDC. Select the proper cable to construct your network. Use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections 100Ω Category 3, 4, or 5 cable for 10Mbps connections, 100Ω Category 5 cable for 100Mbps, or 100Ω...
  • Page 103: Technical Specification

    Technical Specification The 8 10/100TX plus 2 100FX managed industrial switch technical specification is following. Standard Protocol Management RFC Standard Manual Documentation Number: EIR510-xSFP-T_0708m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics –...
  • Page 104 Up to 3 Trap stations Cold start, Port link up, Port link down, Authentication Failure, SNMP Trap Private Trap for power status, Port Alarm configuration, Fault alarm, X-ring topology change Technology Store and forward switching architecture 14,880 pps for 10Base-T Ethernet port Transfer Rate 148,800 pps for 100Base-TX/FX Fast Ethernet port 4 types of packet filter rule with different packet combination:...
  • Page 105 Optical cable Back-plane 2.0 Gbps Packet throughput 2.976Mpps at @64bytes ability 24 ~48 VDC Power Supply Redundant power with polarity reverse protects function and removable terminal block. Power 11.28 Watts consumption 2 ports for X-Ring to provide redundant backup feature and the recovery time below 300ms and start by Web interface X-Ring management.
  • Page 106 IGMP v1, v2 and Query mode IGMP Up to 256 multicast groups. Support SMTP Server and 6 e-mail accounts for receiving SMTP event alert SNTP Support SNTP to synchronize system clock in Internet Management IP IP address security to prevents unauthorized intruder security TX packet only Port mirror...
  • Page 107 DIN rail kit and wall mount ear for wall mount or DIN-type Install cabinet install -40℃ to 75℃ Operating Temp. Operating 5% to 95% (Non-condensing) Humidity Storage -40℃ to 85℃ Temperature Case IP30 Dimensions 2.7 x 4.2 x 6.4 in (7.4 x 10.7 x 16.13 cm) FCC Class A CE EN61000-4-2 CE EN61000-4-3...

This manual is also suitable for:

Elinx eir510-2mt-tElinx eir510-2sc-tElinx eir510-2xx-t

Table of Contents

Save PDF