Download Print this page
Black Box LES424A Quick Start Manual

Black Box LES424A Quick Start Manual

4-port hardened serial server
Hide thumbs Also See for LES424A:

Advertisement

Quick Links

LES424A Quick Start Guide
Reset switch operation.
Hold in Reset (mode) switch for...
Result
0 to 2 seconds
Initiates a hardware reset.
2 to 10 seconds
Enters Console mode.
More than 10 seconds
Resets to factory defaults.
Serial Port Pinout — DB9
Table B-1. DB9 M connector pinout.
DB9
M
Direction
RS-422/485
Pin
RS-232
(RS-232)
4-Wire
1
DCD
Input
RDA (-)
2
RD
Input
RDB (+)
3
TD
Output
TDB (+)
4
DTR
Output
TDA (-)
5
GND
GND
6
DSR
Input
7
RTS
Output
8
CTS
Input
9
Specifications
Certifications — FCC Part 15 Class A, CE, NEMA TS2
Enclosure — Rating: IP30;
Mounting: DIN rail mount (35 mm);
Size: 1.8"H x 4.4"W x 6.75"D (4.57 x 12.2 x
17.1 cm)
724-746-5500 | blackbox.com
Black Box Tech
Support: FREE! Live.
24/7. Tech support
the way it should be.
Great tech support is just 30 seconds
away at 724-746-5500 or blackbox.com.
Specifications (Continued from page 5)
Environment — Operating Temperature: -40 to
+176° F (-40 to +80° C);
Storage Temperature: -40 to +185° F (-40 to
+85° C);
Operating Humidity: 10 to 95%, noncondensing
Power Supply — Voltage requirements: 10- to
RS-485
58-VDC;
2-Wire
Consumption: 6.0 watts maximum
Customer
Support
Data B (+)
Information
Data A (-)
GND
© Copyright 2013. Black Box Corporation. All rights reserved.
Black Box and the Double Diamond logo are registered trademarks of
BB Technologies, Inc. UL is a registered trademark of Underwriters
Laboratories. Any other trademarks mentioned in this manual are
acknowledged to be the property of the trademark owners.
LES424A Quick Start Guide, rev. 1
724-746-5500 | blackbox.com
Page 5
BLACK BOX
Order toll-free in the U.S.:
Call 877-877-BBOX
(outside U.S. call 1-724-746-5500)
FREE technical support
24 hours a day, 7 days a week:
Call 724-746-5500 or
fax 724-746-0746
Mailing address:
Black Box Corporation
1000 Park Drive
Lawrence, PA 15055-1018
Web site: www.blackbox.com
E-mail: info@blackbox.com
Page 6
4-Port Hardened Serial Server
Quick Start Guide
®
Step 1. Install/Connect the Hardware.
• Unpack your serial server from the shipping
container. Verify that all included items are
present.
- 4-Port Hardened Serial Server
- CD with Hardened Serial Server Software
- (2) panel mount adapters and (4) mounting
screws
- DIN rail mount adapter and (3) mounting
screws
- This Quick Start Guide
• Mount the serial server using panel or DIN rail
mount adapters.
• Connect a 10- to 58-VDC power supply
(6.0 W required).
• Connect to the network (using a standard
Ethernet cable).
• Connect the serial devices (using an RS-232
with DB9 cable, straight-through for DCE
device, null-modem for DTE device).
724-746-5500 | blackbox.com
LES424A
BLACK B

Advertisement

loading

Summary of Contents for Black Box LES424A

  • Page 1 • Connect the serial devices (using an RS-232 © Copyright 2013. Black Box Corporation. All rights reserved. Enclosure — Rating: IP30; Black Box and the Double Diamond logo are registered trademarks of with DB9 cable, straight-through for DCE Mounting: DIN rail mount (35 mm);...
  • Page 2 • General Setup. - Insert the Black Box Hardened Serial Server Software client or the server in the pair, and set up the IP - Enter a name for the serial server. This name will CD into the computer.