2.2 Display

3 ½ digit, 15mm LCD display
2.3 Hold Button
Press to keep the current reading on the display.
Press the button again to return to normal display.

2.4 Rotary Switch

The rotary switch is used to switch between functions/
ranges.Functions are: voltage, current, resistance, diode,
continuity and transistor gain.

2.5 Input Jacks

VΩmA:voltage
resistance
,
measurement input
COM Common lead input
:
10A:
Greater than 200mA current measurement input
(
red test lead
)

2.6 Automatic Power Off

After 15 min. of non-use the meter will automatically turn
itself off.To turn the meter back on, move the rotary
switch to any position except off.
2.7 Accessoies
Manual
Test Leads
Case
Multifunction Socket
9V Battery
mA current
diode
continuity
,
,
,
red test lead
(
)
(
black test lead
)
1piece
1pair
1piece
1piece
1piece
05

3. Specifications

3.1 General Specifications

Range
Function
Safety Rating
600V CAT III
Pollution degree
2
Operating Altitude
<2000m
Operating Temperature/
0~40°C, (<80% RH)
Humidity
Storage Temperature/
-10~60°C, (<70% RH, remove battery)
Humidity
Temperature
0.1xaccuracy/0°C (<18°C or >28°C)
coefficient
Max. Input between
terminals and earth
600V DC or AC rms
ground
F1 250mA/250V
Fuse Protection
F2 10A/600V
Sample Rate
Approx. 3 times/sec,
Display
3 ½ digit LCD display,max. reading: 1999.
Over-range Indication display shows"1"
When battery voltage drops below the
Low Battery Indication
normal operating voltage,"
appear on the display.
Polarity Indication
Display automatically displays "-"
9V battery NEDA 1604 or 6F22
Power
158(L)x74(W)x36(H) mm.
Dimensions
approx. 220g (including battery)
Weight