ring terminal that accommodates a #8 screw, and is UL/CSA approved.
Recommended tightening torque is 20 lbf-in (2.3 N-m).
CAUTION: Ensure the total cable distance from the inverter to
the battery is within the requirement of Section 2.4.1 (DC Wire
Sizing).
9.
Once the entire installation is complete, and all connections are verifi ed,
close the fuse disconnect (or circuit breaker) to provide power to the
inverter.
bolt
battery
post

Figure 2-4, DC Cable to Battery Terminals

CSW1012
Inverter

Figure 2-5, DC Cable to Inverter's DC Terminals

© 2013 Magnum Energy, Inc.
nut
lock washer
battery terminal
flat washer
DC cable lugs are flush
with the battery terminals.
Inverter's DC
+ terminal
Ensure nothing is placed
between the DC terminal
and the ring lug.
2.0 Installation
DC cable
with ring lug
BATTERY
Verify that the
M6-1.0 Hex nut
Lock washer
#12 Flat washer
DC cable
with ring lug
CAUTION:
13