2.0 Installation
2.2.2
Mounting the Inverter
Review the information in this section before mounting the inverter.
Orientating the Inverter
When mounted indoors, the CSW1012 inverter can be mounted on/underneath
a horizontal surface (shelf or table) or on a vertical surface (wall or bulkhead)
with the DC terminals facing left, right, or up—do not mount with the DC
terminals facing downward (see Figure 2-2). When mounted in an RV, mount
flat on a horizontal surface only.
Securing the Inverter
After determining your mounting position, use the base of the inverter's
chassis as a template to mark your mounting screw locations (or, refer to the
dimensions in Figure 2-3). Remove the inverter and drill pilot holes into the
mounting surface. Secure the inverter to the surface using the appropriate
corrosion-resistant hardware (sized #10 – not supplied). If this unit is used
in a mobile application, you may want to place flexible washers or bushings
between the mounting surface and the inverter's mounting flanges to reduce
vibration.
For Indoor Use:
For RV Installation:
Figure 2-2, Approved Mounting Positions
6
Mount flat on a
horizontal surface only
© 2013 Magnum Energy, Inc.
DO NOT mount with
DC terminals facing downward