Accuracy (cont'd)
Resistance and Conductance (Conductance on DM-820A, DM-830A, and DML-430A Only)
Range
600.0 Ω
± (0.1% + 0.3 Ω)
6.000 kΩ
± (0.1% + 0.003 kΩ)
60.00 kΩ
± (0.1% + 0.03 kΩ)
600.0 kΩ
± (0.1% + 0.3 kΩ)
6.000 MΩ
± (0.4% + 0.003 MΩ)
60.00 MΩ
± (1.5% + 0.05 MΩ)
99.99 nS
± (0.8% + 0.1 nS)
Continuity
Tone Threshold: Between 20 Ω and 300 Ω
Response Time: < 100 µs
Capacitance
Range
60.00 nF
± (0.8% + 0.03 nF)
600.0 nF
± (0.8% + 0.3 nF)
6.000 µF
± (1.0% + 0.003 µF)
60.00 µF
± (2.0% + 0.03 µF)
600.0 µF
(2)
± (3.5% + 0.5 µF)
6.000 mF
(2)
± (5.0% + 0.005 mF)
25.00 mF
(2)
± (6.5% + 0.05 mF)
(1)
Accuracies with film capacitor or better
(2)
In manual ranging mode, measurements are not specified below 50.0 µF, 0.54 mF, and 5.4 mF for
600.0 µF, 6.000 mF and 25.00 mF ranges, respectively
Diode Test
Measuring Range: 2.000 V
Test Current (typical): 0.4 mA
Open Circuit Voltage: < 3.5 VDC
Accuracy: 1.0% + 0.001 V