DESCRIPTION

3.2 APPLICATION EXAMPLE

The following shows a schematic application example of an electric vehicle charging post with Mainpine components . For example, feeder
option A has a circuit breaker and an Insta contactor . Feeder option B has a circuit breaker and a SIRIUS power contactor .
Digital
E Meter
Option
Surge
Arrester
Type 2
Digital
E Meter
Option
Surge
Arrester
Type 2

3.3 FUNCTION DESCRIPTION

SEQUENCE OF CHARGING PROCESS
1. INITIALIZATION
After the operating voltage is applied, the module carries out initializations and function tests indicated by an LED flashing
sequence (which begins and ends with a two-second white indication) and then waits for vehicle connection .
2. CHARGING PROCESS
The module waits for a charging cable or vehicle to be connected (status A) and continually blinks the blue LED . If an approved
connecting cable has been connected (see Proximity) and status B is indicated by the vehicle, the module changes the LED to be
steady-blue and activates the interlock .
After interlocking, the charging enable P1/P2, P3/P4 or P4/P5 is activated (see Proximity) if the vehicle is signaling status C . The
charging process is activated, and the LED is changed to steady-green . If status D is indicated (ventilation required) then charging
and interlock are deactivated as the EPC does not provide a fan-enable mechanism, and the LED is changed to steady-red .
In the fault condition the charge enable P1/P2, P3/P4, or P5/P6 and the interlock are deactivated and the LED is changed to
continually blink red .
6
Ground
Fault
Operated
Circuit
Interrupter
A
Ground
Fault
Operated
Circuit
Interrupter
B
Miniature
Insta
Circuit
Contactor
Breaker
Mainpine
EPC Charging
Controller
Circuit
SIRIUS
Breaker
Power
Contactor
Mainpine
EPC Charging
Controller
Socket Outlet