SYSTEMS PERFORMANCE—RJNA- SERIES
COOLING PERFORMANCE DATA—RJNA-A060
wbE
CFM [L/s]
2500 [1180]
DR ➀
Total BTUH [kW]
74.9 [21.95]
75
Sens BTUH [kW]
44.2 [12.95]
[23.9]
Power
O
Total BTUH [kW]
74.4 [21.80]
U
80
T
Sens BTUH [kW]
44.3 [12.98]
[26.7]
D
Power
O
O
Total BTUH [kW]
73.3 [21.48]
85
R
Sens BTUH [kW]
43.8 [12.84]
[29.4]
Power
D
R
Total BTUH [kW]
71.8 [21.04]
Y
90
Sens BTUH [kW]
43.0 [12.60]
[32.2]
Power
B
U
Total BTUH [kW]
70.0 [20.51]
L
95
Sens BTUH [kW]
41.9 [12.28]
B
[35]
Power
T
Total BTUH [kW]
68.0 [19.93]
E
100
M
Sens BTUH [kW]
40.7 [11.93]
[37.8]
P
Power
E
R
Total BTUH [kW]
66.0 [19.34]
105
A
Sens BTUH [kW]
39.6 [11.61]
T
[40.6]
Power
U
R
Total BTUH [kW]
64.1 [18.79]
E
110
Sens BTUH [kW]
38.5 [11.28]
[43.3]
°F
Power
[°C]
Total BTUH [kW]
62.4 [18.29]
115
Sens BTUH [kW]
37.8 [11.08]
[46.1]
Power
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
HEATING PERFORMANCE DATA—RJNA-A060
IDB
CFM [L/s]
2500 [1180]
0
Total BTUH [kW]
16.6 [4.86]
O
[-17.8]
Power
U
T
5
Total BTUH [kW]
22.7 [6.65]
D
[26.7]
Power
O
O
10
Total BTUH [kW]
28.5 [8.35]
R
[-12.2]
Power
D
15
Total BTUH [kW]
34.0 [9.96]
R
[32.2]
Power
Y
20
Total BTUH [kW]
39.1 [11.46]
B
[-6.6]
Power
U
L
25
Total BTUH [kW]
43.9 [12.87]
B
[37.8]
Power
T
30
Total BTUH [kW]
48.4 [14.18]
E
[-1.1]
Power
M
P
35
Total BTUH [kW]
52.6 [15.42]
E
[43.3]
Power
R
A
40
Total BTUH [kW]
56.4 [16.53]
T
[4.4]
Power
U
R
45
Total BTUH [kW]
59.9 [17.55]
E
[46.1]
Power
°F
50
Total BTUH [kW]
63.1 [18.49]
[°C]
[10]
Power
IDB—Indoor air dry bulb
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
71°F [21.7°C]
2000 [944]
1500 [708]
.22
.19
.15
71.6 [20.98]
68.4 [20.05]
39.6 [11.61]
35.0 [10.26]
4.0
3.9
3.8
71.2 [20.87]
67.9 [19.90]
39.7 [11.63]
35.0 [10.26]
4.2
4.1
4.1
70.2 [20.57]
67.0 [19.64]
39.2 [11.49]
34.7 [10.17]
4.5
4.4
4.3
68.7 [20.13]
65.6 [19.23]
38.5 [11.28]
34.0 [9.96]
4.7
4.6
4.5
67.0 [19.64]
63.9 [18.73]
37.5 [10.99]
33.2 [9.73]
4.9
4.8
4.7
65.1 [19.08]
62.1 [18.20]
36.5 [10.70]
32.2 [9.44]
5.1
5.0
4.9
63.1 [18.49]
60.3 [17.67]
35.4 [10.37]
31.3 [9.17]
5.4
5.3
5.1
61.3 [17.97]
58.5 [17.14]
34.5 [10.11]
30.5 [8.94]
5.6
5.5
5.4
59.7 [17.50]
57.0 [16.71]
33.8 [9.91]
29.9 [8.76]
5.8
5.7
5.6
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
60°F [15.5°C]
2000 [944]
1500 [708]
16.3 [4.78]
16.0 [4.69]
3.0
3.1
3.2
22.3 [6.54]
21.9 [6.42]
3.1
3.2
3.3
28.0 [8.21]
27.5 [8.06]
3.2
3.3
3.4
33.4 [9.79]
32.8 [9.61]
3.3
3.4
3.5
38.4 [11.25]
37.7 [11.05]
3.4
3.5
3.6
43.2 [12.66]
42.4 [12.43]
3.5
3.6
3.7
47.6 [13.95]
46.7 [13.69]
3.5
3.7
3.8
51.7 [15.15]
50.7 [14.86]
3.6
3.7
3.9
55.4 [16.24]
54.5 [15.97]
3.7
3.8
4.0
58.9 [17.26]
57.8 [16.94]
3.8
3.9
4.1
62.0 [18.17]
60.9 [17.85]
3.9
4.0
4.1
67°F [19.4°C]
2500 [1180]
2000 [944]
1500 [708]
.22
.19
71.3 [20.90]
68.2 [19.99]
65.1 [19.08]
53.4 [15.65]
47.8 [14.01]
42.3 [12.40]
3.9
3.9
70.8 [20.75]
67.7 [19.84]
64.6 [18.93]
53.5 [15.68]
47.9 [14.04]
42.3 [12.40]
4.2
4.1
69.7 [20.43]
66.7 [19.55]
63.6 [18.64]
53.0 [15.53]
47.5 [13.92]
41.9 [12.28]
4.4
4.3
68.2 [19.99]
65.2 [19.11]
62.3 [18.26]
52.2 [15.30]
46.7 [13.69]
41.3 [12.10]
4.6
4.5
66.4 [19.46]
63.5 [18.61]
60.6 [17.76]
51.1 [14.98]
45.8 [13.42]
40.4 [11.84]
4.8
4.7
64.4 [18.87]
61.6 [18.05]
58.8 [17.23]
49.9 [14.62]
44.7 [13.10]
39.5 [11.58]
5.1
5.0
62.4 [18.29]
59.7 [17.50]
56.9 [16.68]
48.8 [14.30]
43.7 [12.81]
38.6 [11.31]
5.3
5.2
60.5 [17.73]
57.8 [16.94]
55.2 [16.18]
47.7 [13.98]
42.7 [12.51]
37.8 [11.08]
5.5
5.4
58.8 [17.23]
56.2 [16.47]
53.7 [15.74]
47.0 [13.77]
42.1 [12.34]
37.2 [10.90]
5.7
5.6
NOTES:
➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
70°F [21.1°C]
2500 [1180]
2000 [944]
1500 [708]
15.0 [4.40]
14.7 [4.31]
14.4 [4.22]
3.4
3.5
21.1 [6.18]
20.7 [6.07]
20.3 [5.95]
3.5
3.6
26.9 [7.88]
26.4 [7.74]
25.9 [7.59]
3.6
3.7
32.3 [9.47]
31.8 [9.32]
31.2 [9.14]
3.7
3.8
37.5 [10.99]
36.8 [10.79]
36.2 [10.61]
3.8
3.9
42.3 [12.40]
41.5 [12.16]
40.8 [11.96]
3.9
4.0
46.8 [13.72]
46.0 [13.48]
45.1 [13.22]
4.0
4.1
50.9 [14.92]
50.1 [14.68]
49.2 [14.42]
4.0
4.2
54.8 [16.06]
53.8 [15.77]
52.9 [15.50]
4.1
4.3
58.3 [17.09]
57.3 [16.79]
56.3 [16.50]
4.2
4.4
61.5 [18.02]
60.4 [17.70]
59.3 [17.38]
4.3
4.5
18
63°F [17.2°C]
2500 [1180]
2000 [944]
.15
.22
.19
67.6 [19.81]
64.6 [18.93]
57.5 [16.85]
51.5 [15.09]
3.8
3.9
3.8
67.1 [19.67]
64.2 [18.82]
57.6 [16.88]
51.5 [15.09]
4.0
4.1
4.1
66.0 [19.34]
63.1 [18.49]
57.1 [16.73]
51.1 [14.98]
4.2
4.4
4.3
64.5 [18.90]
61.7 [18.08]
56.3 [16.50]
50.4 [14.77]
4.4
4.6
4.5
62.7 [18.38]
60.0 [17.58]
55.2 [16.18]
49.4 [14.48]
4.6
4.8
4.7
60.7 [17.79]
58.1 [17.03]
54.0 [15.83]
48.4 [14.18]
4.9
5.0
4.9
58.7 [17.20]
56.1 [16.44]
52.8 [15.47]
47.3 [13.86]
5.1
5.3
5.2
56.8 [16.65]
54.3 [15.91]
51.8 [15.18]
46.4 [13.60]
5.3
5.5
5.4
55.1 [16.15]
52.7 [15.44]
51.1 [14.98]
45.7 [13.39]
5.5
5.7
5.6
80°F [26.7°C]
2500 [1180]
2000 [944]
14.9 [4.37]
14.6 [4.28]
3.7
3.9
4.1
21.0 [6.15]
20.6 [6.04]
3.7
4.0
4.2
26.8 [7.85]
26.3 [7.71]
3.8
4.1
4.2
32.3 [9.47]
31.7 [9.29]
3.9
4.2
4.3
37.4 [10.96]
36.8 [10.79]
4.0
4.3
4.4
42.2 [12.37]
41.5 [12.16]
4.1
4.4
4.5
46.7 [13.69]
45.9 [13.45]
4.2
4.5
4.6
50.9 [14.92]
50.0 [14.65]
4.3
4.6
4.7
54.7 [16.03]
53.8 [15.77]
4.4
4.6
4.8
58.2 [17.06]
57.2 [16.76]
4.5
4.7
4.9
61.4 [17.99]
60.4 [17.70]
4.6
4.8
5.0
[ ] Designates Metric Conversions
1500 [708]
.15
61.7 [18.08]
45.5 [13.33]
3.8
61.2 [17.94]
45.5 [13.33]
4.0
60.3 [17.67]
45.2 [13.25]
4.2
58.9 [17.26]
44.5 [13.04]
4.4
57.2 [16.76]
43.7 [12.81]
4.6
55.4 [16.24]
42.7 [12.51]
4.8
53.6 [15.71]
41.8 [12.25]
5.1
51.8 [15.18]
41.0 [12.02]
5.3
50.3 [14.74]
40.4 [11.84]
5.5
1500 [708]
14.4 [4.22]
4.2
20.3 [5.95]
4.3
25.9 [7.59]
4.4
31.1 [9.11]
4.5
36.1 [10.58]
4.6
40.7 [11.93]
4.7
45.1 [13.22]
4.8
49.1 [14.39]
4.8
52.8 [15.47]
4.9
56.2 [16.47]
5.0
59.3 [17.38]
5.1

Hide quick links: