The equipment room must also meet strict limits on salts, acids, and sulfides to eliminate corrosion
and premature aging of components, as shown in
Table 4 Harmful gas limits in the equipment room
Gas
SO
2
H
S
2
NH
3
Cl
2

Cooling system

The MSR3012/3024 router uses left to right airflow for heat dissipation, and the MSR3044/3064
router uses left to rear airflow for heat dissipation.
Figure 1 Airflow through the MSR3012/3024 chassis
Figure 2 Airflow through the MSR3044/3064 chassis
To ensure good ventilation, the following requirements must be met:
The air inlet and outlet vents are not blocked, and leave at least 10 cm (3.94 in) of clearance.
The installation site has a good cooling system.
Table
3
Max. (mg/m
)
0.2
0.006
0.05
0.01
3