Renesas TQFP-100G User Manual
Renesas TQFP-100G User Manual

Renesas TQFP-100G User Manual

H8s/2237series user system interface cable

Advertisement

Quick Links

To our customers,
st
On April 1
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
Old Company Name in Catalogs and Other Documents
Renesas Electronics website:
http://www.renesas.com
st
April 1
, 2010
Renesas Electronics Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Renesas TQFP-100G

  • Page 1 On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
  • Page 2 Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
  • Page 3 H8S/2237Series TQFP-100G User System Interface Cable (HS2237ECN61H) for E6000 Emulator User’s Manual...
  • Page 4 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document.
  • Page 5: Preface

    The HS2237ECN61H is a user system interface cable that connects an H8S/2633 series E6000 emulator (HS2633EPI61H; hereinafter referred to as the emulator) to the IC socket for a TQFP-100G package (package code: TFP-100G) for the H8S/2237 series MCU on the user system.
  • Page 6: Table Of Contents

    Preface ...i Section 1 Configuration...1 Section 2 Connection Procedures ...4 Connecting User System Interface Cable to Emulator Station ... 4 Connecting User System Interface Cable to User System ... 5 2.2.1 Installing IC Socket ... 6 2.2.2 Inserting Cable Head ... 7 2.2.3 Fastening Cable Head ...
  • Page 7: Section 1 Configuration

    Section 1 Configuration Use an NQPACK100SE socket (manufactured by Tokyo Eletech Corporation) for the TFP-100G package IC socket on the user system. Figure 1 shows the configuration of the HS2237ECN61H user system interface cable for the TFP-100G package. UTION...
  • Page 8 To emulator station Cable body Screws (M2 x 10 mm) (for fastening cable head) Screws (M2 x 6 mm) Socket cover Cable head IC socket User system Figure 1 HS2237ECN61H User System Interface Cable...
  • Page 9 Table 1 lists the HS2237ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS2237ECN61H Components No. Component Cable body Cable head IC socket Socket cover Screws (M2 x 10 mm) Screws (M2 x 6 mm) Guide pins (φ...
  • Page 10: Section 2 Connection Procedures

    Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY.
  • Page 11: Connecting User System Interface Cable To User System

    Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY.
  • Page 12: Installing Ic Socket

    2.2.1 Installing IC Socket 1. Confirming the location of IC socket After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket, and fasten it to the user system. Use the guide pins provided to determine where to install the IC socket, as shown in figure 3.
  • Page 13: Inserting Cable Head

    2.2.2 Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a TFP-100G package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 4.
  • Page 14 Fasten the user system interface cable head to the IC socket for a TFP-100G package on the user system with the four screws (M2 time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
  • Page 15: Connecting Cable Body To Cable Head

    2.2.4 Connecting Cable Body to Cable Head Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 5 Fastening Cable Body...
  • Page 16: Recommended Dimensions For User System Mount Pad

    Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an TFP-100G package (NQPACK100SE: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad.
  • Page 17: Dimensions For User System Interface Cable Head

    Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Unit: mm Tolerance: –0.5 mm Figure 7 Dimensions for User System Interface Cable Head...
  • Page 18: Resulting Dimensions After Connecting User System Interface Cable

    Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Cable head IC socket (NQPACK100SE User system manufactured by Tokyo Eletech Corporation) Figure 8 Resulting Dimensions after Connecting User System Interface Cable Unit: mm...
  • Page 19: Section 3 Installing The Mcu To The User System

    Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 20 Screws (M2 x 6 mm) Socket cover Pin 1 IC socket (NQPACK100SE manufactured by Tokyo Eleteck Corporation) User system Figure 9 Installing MCU to User System...
  • Page 21: Section 4 Verifying Operation

    Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2633 series, turn on the emulator according to the procedures described in the E6000 Series Emulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins with the MEMORY_FILL command (emulator command).
  • Page 22: Section 5 Notice

    1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.

Table of Contents