LG GCS165SV Service Manual page 9

Color: pcm-super white
Table of Contents

Advertisement

2. RELAY ASSY (PTC AND OLP)
Normal operation of
Compressor is
impossible or poor.
Separate the Relay Assy
from Compressor and
measure the resistance
between M and S with a
Tester or Whistone Bridge.
(Figure 21)
Separate the Relay Assy
from the Compressor and
check the resistance value
between two terminals of
OLP with a Tester.
C
M
S
F
g i
u
e r
2
1
Observation value is
220V/50Hz : 22Ω±30%
115V/60Hz : 6.8Ω±30%
240V/50Hz : 33Ω±30%
127, 220V/60Hz :
22Ω±30%
The resistance value is 0
or serveral hundreds Ω.
The value is ∞.
YES
Check another
electric components.
NO
Replace Relay Assy.
C
M
S
F
g i
u
e r
-9-
Check another
electric
components.
Replace
Relay Assy.
T
L
N
3
2
2
2

Advertisement