Troubleshooting [To Be Performed By Trained Service Providers Only] - Page 1 Of 3 - Oasis CO34R Installation And Operating Manual

Open refrigerated self-service merchandiser
Table of Contents

Advertisement

TROUBLESHOOTING [TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY] - PAGE 1 of 3

CONDITION
Water Is On Floor Caution! Water on flooring can cause much damage! Until cause is determined (and
repaired), follow these procedures:


Check that the drain trap is free of debris.
Check that all of the hoses are connected.
Check that condensate pan is properly plugged in or connected.
Check that condensate pan float is operating properly (electric coil condensate units
only).
Check that the drain hose is correctly positioned over condensate pan (or floor drain,
for remote units).
Check store conditions. To prevent condensation in Type 1 environments, maximum
conditions are to be 55% humidity / 75° Fahrenheit. For Type 2 environments,
maximum conditions are to be 60% humidity / 80° Fahrenheit. See serial label
(at case rear near main power switch) for Type of case.
Caution! Wicking material (if any on your particular hot gas loop system) may be
dirty or worn and need replacement.


Use wet-dry vacuum (or mop & bucket) to remove standing water.
Use 'catch pans' for water to drain into. Swap out regularly until case has
completely drained.
Slide refrigeration system out from under unit.
After refrigeration system has been carefully slid out from under unit, replace
wicking material with new. If wicking material is not available, contact Structural
Concepts®. See toll-free number at last page of this operating manual.