Preventive Maintenance [To Be Performed By Trained Service Providers] - Page 1 Of 2 - Oasis CO34R Installation And Operating Manual

Open refrigerated self-service merchandiser
Table of Contents

Advertisement

PREVENTIVE MAINTENANCE [TO BE PERFORMED BY TRAINED SERVICE PROVIDERS] - Page 1 of 2

PREVENTIVE
MAINTENANCE
Case Exterior
--- Above photos are taken after rear grille has been removed from case ---
FREQUENCY
Monthly
Condensing Coil:

Remove front panel.

Use vacuum with soft-bristled brush; clean dust and dirt that
may collect on the condenser coil. See illustration below.

Caution! Coil fins are sharp. Handle with care!

Replace rear grille to case (4 screws).

See illustration below.
Quarterly
Clean Sweep™ Condensing Coil (Optional): Disconnect power
from case before cleaning Clean Sweep™ Condenser Coil!

Remove Rear Grille (by removing 4 screws).

Slide/Roll out condensing unit assembly.

Remove the four (4) screws holding the Clean Sweep™ rails
intact.

Remove the Clean Sweep™ rail.

Wash rails' brushes in hot water and mild soap solution.

If brushes are worn, they must be replaced. Call Technical
Service Department to replace. Toll-Free number is listed at
end of manual.

Clean Condensing Coil: Use air pressure or industrial strength
vacuum; clean the dust and dirt that may collect on the
Condenser Coil.

Caution! Coil fins are sharp. Handle with care!

Reattach Clean Sweep rail to condensing unit (4 screws).

Slide/Roll Condensing Unit Assembly back under case.

Replace Rear Grille to case (4 screws).

See photos below.
(4) Screws
INSTRUCTIONS
17
Brushes
Rail

Advertisement

Table of Contents
loading

This manual is also suitable for:

Co44r

Table of Contents