Setting Parameter U085 (Class 532); Checking The Software Version - DURKOPP ADLER 512-211-01 Service Instructions Manual

Hide thumbs Also See for 512-211-01:
Table of Contents

Advertisement

4. Press the Memory button.
5. Press the P5 button.
 The process for downloading to the controller starts. This will take
6. Press the Reset button.
7. Remove the USB stick.
 The software transfer is complete.

12.4.3 Setting parameter U085 (class 532)

After installing new software, parameter U085 must be set for the button
sewing machine.
Prerequisite:
• The machine is in the programming mode, the LED in the Ready button
1. Press and hold the Memory button for 6 seconds.
 The LED in the button illuminates.
2. Select parameter number U085 by using the +/- Program buttons.
3. Press the Ready button.
4. Enter the function value 1 by using the +/- Function buttons.
5. Press the Selection button.

12.4.4 Checking the software version

1. Press and hold the Memory button for 6 seconds.
 The controller beeps 2x; the LED in the button illuminates.
2. Press the +/- Program buttons and select parameter U097.
3. Press the Ready button.
 The current software versions are displayed:
4. Press the +/- Function buttons and check the respective software ver-
5. Press the Ready button.
6. Press the Memory button.
 The LED in the button switches off.
62
approx. 4 minutes.
is off.
• M X.XX = Main program
• P X.XX = Control panel
• T X.XX = Servo motors
• A X.XX = Sewing patterns
sion.
Service settings via software
Service Instructions 512-211-01/532-211-01 - 00.0 - 06/2016