Vitoconnect 100, Type Opto1; Lon Connecting Cable For Data Exchange Between Control Units - Viessmann Vitodens 300-W Technical Manual

Hide thumbs Also See for Vitodens 300-W:
Table of Contents

Advertisement

Control units
(cont.)

Vitoconnect 100, type OPTO1

Part no. Z014 494
■ Internet interface for remote control of a heating system with
1 heat generator via WLAN with DSL router
■ Compact device for wall mounting
■ For system operation with ViCare app and/or Vitoguide
Functions when operating with the ViCare app
■ Calling up the temperatures of connected heating circuits
■ Intuitive adjustment of desired temperatures and time programs for
central heating and DHW heating
■ Easy transmission of system data, e.g. fault messages via email or
telephone communication with the heating contractor
■ Heating system fault reporting by push notification
The ViCare app supports the following end devices:
■ End devices with Apple iOS operating system
■ End devices with Google Android operating system
Note
■ For compatible versions, see App Store or Google Play
■ For further information, see www.vicare.info. and technical guide
"Connectivity with WLAN and Vitoconnect".
Functions when operating with Vitoguide
■ Monitoring of heating system following enabling of the system by
the system user
■ Access to operating programs, set values and time programs
■ Scanning system information for all connected heating systems
■ Display and forwarding of fault messages in plain text
Vitoguide supports the following end devices:
■ Terminal devices with a screen size of 8 inches or larger
Note
For more information, see www.vitoguide.info.
Standard delivery
■ WLAN module for connection with the DSL router, for wall mount-
ing
■ Connection line with Optolink/USB (WLAN module/boiler control
unit, 3 m long)
■ Power cable with plug-in power supply unit (1 m long)
On-site requirements
■ Compatible heating system with Vitoconnect 100, type OPTO1
Note
For supported control units, see www.viessmann.com/vitocon-
nect
■ Before commissioning, check the system requirements for commu-
nication via local IP networks/WLAN.
7
■ Internet connection with flat rate data (without time or volume
restrictions)

LON connecting cable for data exchange between control units

Part no. 7143 495
VIESMANN
108
Specification
2 0
Specification
Power supply via plug-in
230 V~/5 V–
power supply unit
Rated current
1 A
Power consumption
5 W
Protection class
II
IP rating
IP 30 to EN 60529; ensure through de-
sign/installation.
Permissible ambient temperature
– Operation
–5 to +40 °C
Installation in living spaces or installa-
tion rooms (standard ambient condi-
tions)
– Storage and transport
–20 to +60 °C
WLAN frequency
2.4 GHz
Cable length 7 m, fully wired.
VITODENS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 200-wVitodens 222-w

Table of Contents