Hrr 4104 Alarms - Harmonic HRR 4104 Product Manual

Return path receiver
Table of Contents

Advertisement

User Interface Options
3.4

HRR 4104 Alarms

The HRR 4104 provides alarms relating to the module as a whole, as well as
alarms within the specific receivers (A through D). Table 3-2 describes the
alarms for the HRR 4104 Return Path Receiver.
When there is an alarm, the Status LED on the front panel of the HRR 4104
module illuminates red. In addition, every alarm is reported via SNMP and
via the HLP 4200WD front panel display. For information on accessing the
alarms via the HLP 4200WD front panel display, see Section 3.1.
Table 3-2:
HRR 4104 Alarms
Alarm
Module Alarms
Module Low 5 V PS
Module High 5 V PS
Module Heat Sink Temp High
Receiver Alarms
Receiver Low Optical Input
Receiver Muted Manually
Receiver AGC Beyond Limits
3–8
Description
Power supply voltage is below 4.5 V
Power supply voltage is above 5.5 V
Heat sink temperature is above 80° C (176° F)
Optical input is below the optical alarm limit
Receiver has been set to Mute: Forced
Gain control is too low or too high (AGC is
enabled)
Copyright © 2005 Harmonic Inc.