® to meet the most stringent demands where hygiene and mobility are concerned The operating principle of the Medela Lactina is to simulate the natural, physiological conditions encountered in breastfeeding The pump motor and the suction source are completely separate All...
Page 5
The Purchaser shall bear all responsibility and expense for returning this product to Medela, including risk of loss prior to receipt by Medela, and shipping, packing, and insurance costs...
50 / 60 Hz 50 VA °C Alternating current Operation T 1.25 A 6.3 x32 250 V 12 V DC Medela Art Nr. 928.7001 Transport/Storage 16 W 1.25 410 mm 150 mm Protection class Type B Please see accompanying papers...
– Swing out the pumping arm (2) fully by hand – Lock the return spring by inserting the spring holder (14) obtainable from Medela in the slot provided for this purpose (see exploded view diagram) – Swing in pumping arm (2) –...
2.1.5 Assembly Assembly is performed in the reverse sequence to dismantling. The following points should also be noted: – S equence of cable routing from top to bottom: mains lead from SPS, potentiometer (RV1), switch, LED (D1) – The SPS must be placed right at the rear of the case and the cables must be pressed fully into their holders –...
2.1.6 Final Test Procedure a) General checks – 100% check (visual) of type designation, serial no, DC plate 12 V and labeling on back – 100% check with respect to air gap between swivel arm and case with leaf gauge Permissible air gap 02–15 mm; if the air gap is outside this range reject unit and replace –...
Uses • To initiate and maintain a milk supply as well as collect breastmilk at work or during other absences from the baby • To initiate and maintain a milk supply if direct breastfeeding is not pos- sible • To relieve engorgement Single pumping with simultaneous massage is helpful to relieve engorgement Cleaning and Sterilization Unless instructed otherwise by your healthcare provider.
Rinse in clear water • Air-dry on clean towel and cover parts when not in use All parts may also be washed in top rack of dishwasher For Quicker Cleaning: Medela offers Quick Clean Micro-Steam bags for daily kit ™ ™...
4. Precautionary Measures / Troubleshooting The breastpump should only be used in a dust-free environment Do not use or set the pump where it is exposed to direct sunlight or any other source of heat What to do when... – the pump does not run when it is switched on: Check whether the Lactina breastpump is properly connected to ®...
The design of your Medela Lactina breastpump means that routine servicing is not normally uneccessary All bearings are maintenance-free and, when used as directed (ie only in a dust-free environment and...
To ensure that the breastpump will provide trouble-free operation for years to come, it should be examined periodically according to the following checklist Checklist: 1 The specification of the fuse employed as well as the power supply to which the pump is connected must match the data on the pump specification plate 2 Fit the accessories to the breastpump as described in the instructions for use (included with the accessory kit) The...
– the electrical installation within the room concerned satisfies IEC requirements (in the course of preparation). – the unit is used as specified in the instructions for use – accessory kits used on Lactina breastpumps are authorized by Medela, Inc...
Need help?
Do you have a question about the lactrina and is the answer not in the manual?
Questions and answers