5 | LED descriptions
The B426 module includes the following on-board LEDs to assist
with troubleshooting issues.
Flash pattern Function
Flashes once
Normal state: Indicates normal operation state.
every 1 sec
3 quick fl ashes
Communication error state: Indicates a bus
every 1 sec
communication error. The module is not
receiving commands from the control panel.
On Steady
Trouble state. Indicates a trouble condition
exists.
Off
LED trouble state. Module is not powered, or
some other trouble condition prohibits the
module from controlling the heartbeat LED.
Table 5.1: Heartbeat LED descriptions
Flash pattern Function
RX (Receive)
Occurs when the module receives a message
fl ashes
over the network connection – UPD, TCP, or
DNS.
TX (Transmit)
Occurs when the module sends a message
fl ashes
over the network connection – UPD, TCP, or
DNS.
Table 5.2: RX and TX LEDs descriptions
LINK (yellow)
100mb (green)
Function
fl ash pattern
fl ash pattern
Off
Off
No Ethernet link
On Steady
Off
10 BASE-T link
Flash
Off
10 BASE-T activity
On Steady
On Steady
100 BASE-T link
Flash
On Steady
100 BASE-T activity
Table 5.3: Ethernet LINK and 100mb LEDs descriptions
Condition
Heartbeat
Transmit
Receive
(TX)
(RX)
Network cable
On Steady
Off
1 quick fl ash,
disconnected
repeating
Obtaining an IP
On Steady
Off
2 quick fl ashes,
address
repeating
Low bus
On Steady
Off
3 quick fl ashes,
voltage
repeating
Internal failure
On Steady
On Steady
On Steady
Table 5.4: Trouble conditions indicated through LEDs
6 | Certifi cations
Region
Certifi cation
US
UL 365 – Police Station Connected Burglar Alarm Units and Systems
UL 609 – Local Burglar Alarm Units and Systems
UL 864 – Control Units and Accessories for Fire Alarm Systems (Including NFPA 72)
UL 985 – Household Fire Warning System Units
UL 1023 – Household Burglar Alarm System Units
UL 1076 – Proprietary Burglar Alarm Units and Systems
UL 1610 – Central Station Burglar Alarm Units
FCC Part 15 Class B, NIST FIPS-197 AES Certifi cation
(IP Communications)
Canada
CAN/ULC S303 - Local Burglar Alarm Units and Systems
CAN/ULC S304 - Signal Receiving Centre and Premise Alarm Control Units
ULC-ORD C1023 - Household Burglar Alarm System Units
ULC-ORD C1076 - Proprietary Burglar Alarm Units and
Systems
ICES-003 - Digital Apparatus
EU
EN 50130-4, EN 61000-6-3, EN 60950
Australia
C-Tick
7 | Specifi cations
Dimensions
59.5 mm x 108 mm x 16 mm (2.19 in x 4.25 in x 0.629 in)
Voltage (operating)
12 VDC nominal
Current (maximum)
100 mA max
Connectors
LAN/WAN: RJ-45 modular port (Ethernet)
Ethernet cable
Category 5 or better unshielded twisted pair, 100 m (328 ft) max length
Interface
IEEE 802.3
Data bus wire size
1.02 mm to 0.65 mm (18 AWG to 22 AWG)
Data bus wire length
Maximum distance - Wire size:
150 m (500 ft) - 0.65 mm (22 AWG)
300 m (1000 ft) - 1.02 mm (18 AWG)
Web browser
Microsoft Internet Explorer; Mozilla Firefox
Compatibility
AMAX 2000/2100/3000/4000
B9512G/B9512G-E, B8512G/B8512G-E
B5512/B5512E, B4512/B4512E, B3512/B3512E
D9412GV4/D7412GV4/D7212GV4
D9412GV3/D7412GV3/D7212GV3
D9412GV2/D7412GV2/7212GV2
D9412G/D7412G/D7212G Version 6.3 or higher
D9412/D7412/D7212
D9112
DS7220 Version 2.10 or higher
DS7240 Version 2.10 or higher
DS7400XiV4 Version 4.10 or higher
Easy Series V3+
FPD-7024 Version 1.02 or higher
Solution 2000/3000
Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at
http://www.boschsecurity.com/datecodes/.
14 | Certifi cations
Conettix Ethernet Communication
Module
B426
en Quick Start Guide
For complete installation, configuration, and testing instructions,
refer to the Conettix Ethernet Communication Module (B426) Installation
and Operation Guide provided on the supplied CD-ROM.
Bosch Security Systems, Inc.
Bosch Sicherheitssysteme GmbH
130 Perinton Parkway
Robert-Bosch-Ring 5
Fairport, NY 14450
85630 Grasbrunn
USA
Germany
www.boschsecurity.com
© 2015 Bosch Security Systems, Inc.
F.01U.291.335 | 06 | 2015.08

Advertisement

loading