Electrical Precautions; Outdoor Installation; Indoor Installation; Drainage - Jacuzzi Laser Owner's Manual

Platinum series spas
Hide thumbs Also See for Laser:
Table of Contents

Advertisement

INSTALLATION

Electrical Precautions

CAUTION: Do NOT apply electrical power to the spa
unless it is filled with water to the normal water level,
which is approximately 7" below the spa rim (refer to
location of water level indicator on face of skimmer). If
the spa's motor/pumps are actuated when there is not
sufficient water in the unit, the circulation pump could be
irreparably damaged. Not heeding this caution will
nullify the warranty. In addition to damaging the unit,
operating the unit with insufficient water could cause a
fire.
Do NOT locate lighting fixtures directly above the
spa; lighting and electrical receptacles must be located
at least 5 feet from the spa. Lighting located between 5
and 10 feet from the spa must be on a circuit protected
by a GFCI. (Refer to National Electrical Code, 680-6.)
Do NOT use electrically connected devices, such as
television, radio, telephones, stereo speakers, light or
cooking devices within 5 feet of the spa when the spa is
being used.
All fixed metal objects located within 5 feet of the
spa, such as fence posts, railings, door frames, green-
house structures, gutters, etc., must be attached to the
bonding bar on the outside of the spa electrical cabinet
using #8 solid copper wire. With #8 solid copper wire,
bond the spa to the house electrical panel or ap-
proved local bond.
An approved ground may be an 8 foot long ground
rod, a plate electrode, or a buried metal water pipe with
at least 10 feet of buried pipe. Check your local building
code for requirements. Bonding lugs are available at
your local electrical supply store. (Bond bar location is
shown below.)
(SKIRTS
REMOVED)
ELECTRICAL
CABINET
WIRE
MESH
GRID
SUPPORT, DRAINAGE AND BONDING
DRAIN/FILL VALVE
GRAVEL DRAIN FIELD
6

Outdoor Installation

If you install the spa outdoors, we recommend that
you provide a concrete pad for it to rest on. To do this,
construct forms for a 4" thick level pad. Install a #10
gauge wire mesh 6" x 6" steel reinforced grid. Attach a
#8 solid copper wire to the grid with a ground clamp. This
wire should be long enough to reach the bond bar on the
spa electrical cabinet (minimum 36"), but should NOT be
located under the base of the spa. Then pour the
concrete pad.

Indoor Installation

Water that splashes on the floor during spa use may
cause a walking hazard and/or structural damage. Good
drainage must be provided and proper waterproof build-
ing materials must be used in the area surrounding and
beneath the spa. Take into consideration that high room
humidity will exist due to high spa water temperatures.
Providing natural or forced ventilation of the room will
help maintain comfort and minimize moisture damage to
the building. Jacuzzi Whirlpool Bath is not responsible
for damages resulting from excess moisture or water
spillage. Consult an architect or engineer for aid in
designing your indoor installation.

Drainage

Whether you install your spa indoors or outdoors,
you can drain it completely by attaching a garden hose
to the fill and drain valve located on the pan of the spa.
Simply run the hose to the house sewer line or drain field
and open the drain valve.
Make sure the area surrounding the spa has good
drainage to keep water from collecting at the base of the
spa—especially near the equipment area. If drainage is
poor, install a drain line and/or gravel drain field. (Refer
to illustration below.)
4" THICK CONCRETE PAD
BOND BAR
#8 BOND WIRE
(TO LOCAL BOND)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SantinaPinnacleQuantumTriton

Table of Contents