Electrical Precautions; Outdoor Installation; Drainage; Indoor Installations - Jacuzzi Whirlpool Spa Owner's Manual

Jacuzzi owner's manual whirlpool spa
Table of Contents

Advertisement

Electrical Precautions

CAUTION: Do NOT apply electrical power to the spa
unless it is filled with water to the normal water level,
which is approximately 7" below the spa rim (refer to
location of water level indicator on face of skimmer). If
the spa's motor/pumps are actuated when there is not
sufficient water in the unit, the circulation pump could be
irreparably damaged.
Not heeding this caution will
nullify the warranty. In addition to damaging the unit,
operating the unit with insufficient water could cause a
fire.
Do NOT locate lighting fixtures directly above the
spa; lighting and electrical receptacles must be located
at least 5 feet from the spa. Lighting located between 5
and 10 feet from the spa must be on a circuit protected
by a GFCI. (Refer to National Electrical Code, 680-6.)
Do NOT use electrically connected devices, such as
television, radio, telephones, stereo speakers, light or
cooking devices within 5 feet of the spa when the spa is
being used.
All fixed metal objects located within 5 feet of the
spa, such as fence posts, railings, door frames, green-
house structures, gutters, etc., must be attached to the
bonding bar on the outside of the spa electrical cabinet
using #8 solid copper wire. With #8 solid copper wire,
bond the spa to the house electrical panel or ap-
proved local bond.
An approved ground may be an 8 foot long ground
rod, a plate electrode, or a buried metal water pipe with
at least 10 feet of buried pipe. Check your local building
code for requirements. Bonding lugs are available at
your local electrical supply store. (Bond bar location is
shown below.)
(SKIRTS
REMOVED)
ELECTRICAL
CABINET
WIRE
MESH
GRID
3
www.clearcreekspas.com
INSTALLATION

Outdoor Installation

you provide a concrete pad for it to rest on. To do this,
construct forms for a 4" thick level pad. Install a #10
gauge wire mesh 6" x 6" steel reinforced grid. Attach a
#8 solid copper wire to the grid with a ground clamp.
This wire should be long enough to reach the bond bar
on the spa electrical cabinet (minimum 36"), but should
NOT be located under the base of the spa. Then pour
the concrete pad.

Drainage

you can drain it completely by attaching a garden hose
to the hose bibb (drain valve) located on the suction
plumbing of the spa. Simply run the hose to the house
sewer line or drain field and open the hose bibb.
drainage to keep water from collecting at the base of the
spa—especially near the equipment area. If drainage is
poor, install a drain line and/or gravel drain field. (Refer
to illustration below.)
Indoor Installation
cause a walking hazard and/or structural damage. Good
drainage must be provided and proper waterproof build-
ing materials must be used in the area surrounding and
beneath the spa. Take into consideration that high room
humidity will exist due to high spa water temperatures.
Providing natural or forced ventilation of the room will
help maintain comfort and minimize moisture damage
to the building. Jacuzzi Whirlpool Bath is not respon-
sible for damages resulting from excess moisture or
water spillage. Consult an architect or engineer for aid
in designing your indoor installation.
SUPPORT, DRAINAGE AND BONDING
GRAVEL DRAIN FIELD
If you install the spa outdoors, we recommend that
Whether you install your spa indoors or outdoors,
Make sure the area surrounding the spa has good
Water that splashes on the floor during spa use may
BOND BAR
#8 BOND WIRE
(TO LOCAL BOND)
4" THICK CONCRETE PAD