Kenwood NX-5700 Service Manual page 61

Vhf digital transceiver
Hide thumbs Also See for NX-5700:
Table of Contents

Advertisement

Item
Condition
Panel tuning mode
[NXDN
1) Adj item:
Narrow]
[Nn SQL]
Adjust:[***]
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-1dB
(MOD: 400Hz/
±2.5kHz)
[NXDN
1) Adj item:
Very
[Nv SQL]
Narrow]
Adjust:[***]
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 400Hz/
±1.2kHz)
6.
1) Adj item:
Low
[An LRSSI]
RSSI
Adjust:[***]
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
-118dBm
(0.28μV)
(MOD: 1kHz/
±1.5kHz)
7.
1) Adj item:
High
[An HRSSI]
RSSI
Adjust:[***]
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
-80dBm (22.4μV)
(MOD: 1kHz/
±1.5kHz)
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
SSG
[Open Squelch
Distor-
(NXDN Narrow)]
tion
2) Adj item:
meter
[Low1]→
Oscillo-
[Low3]→
scope
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -1dB
(MOD: 400Hz/
±2.5kHz)
1) Adj item:
SSG
[Open Squelch
Distor-
(NXDN Very Nar-
tion
row)]
meter
2) Adj item:
Oscillo-
[Low1]→
scope
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 400Hz/
±1.2kHz)
1) Adj item:
SSG
[Low RSSI (Analog
Narrow)]
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
-118dBm (0.28μV)
(MOD: 1kHz/
±1.5kHz)
1) Adj item:
SSG
[High RSSI (Analog
Narrow)]
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
-80dBm (22.4μV)
(MOD: 1kHz/
±1.5kHz)
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel
Ext.
SP
con-
nector
Panel ANT
Panel
Ext.
SP
con-
nector
Panel ANT
Panel
Ext.
SP
con-
nector
Panel ANT
Panel
Ext.
SP
con-
nector
Adjustment
Method
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
(No.RA020<Rev.002>)1-61