4.9

Transmitter Section

Item
Condition
Panel tuning
mode
1.
1) Adj item:
Ramp
[RAMPU]
up
Adjust:[****]
Offset
PTT : ON
Press [
] key to
store the adjust-
ment value.
2.
1) Adj item:
Ramp
[RAMPD]
down
Adjust:[****]
Offset
PTT : ON
Press [
] key to
store the adjust-
ment value.
3.
1) Adj item:
High
[H_MAX]
Maxi-
Adjust:[****]
mum
2) Adj item:
Power
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
1-48 (No.RA020<Rev.002>)
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
Power
[Ramp Up Offset]
meter
Press [Transmit]
Ammeter
button.
Press [Apply]
button to store the
adjustment value.
1) Adj item:
Power
[Ramp Down Off-
meter
set]
Ammeter
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
1) Adj item:
Power
[High Maximum
meter
Power]
Ammeter
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
Press [Transmit]
button.
Press [Apply] but-
ton to store the ad-
justment value.
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Adjustment
Method
[PC test mode]
[Automatic Adjust-
ment]
1) Press [Tune Rump
Offset] button.
2) Press [Apply All] but-
ton to store the adjust-
ment value after the
automatic adjustment
has finished.
[Manual Adjustment]
1) Set the adjustment
value to "1".
2) Increase the adjust-
ment value slowly while
monitoring the offset
monitor value.
3) Set the adjustment
value when the offset
monitor value exceed
"50".
[PC test mode]
[Automatic Adjust-
ment]
1) Press [Tune Rump
Offset] button.
2) Press [Apply All] but-
ton to store the adjust-
ment value after the
automatic adjustment
has finished.
[Manual Adjustment]
1) Set the adjustment
value to "1".
2) Increase the adjust-
ment value slowly while
monitoring the offset
monitor value.
3) Set the adjustment
value when the offset
monitor value exceed
"20".
55W
±1W
15A or less
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
Specifica-
tions
/Remarks