4. Product Specification
4.1 Specification
All other specifications than the followings are equivalent to those of the FX Series PLC main unit.
Item
Withstand voltage
General
specification
Insulation resistance
Power supply
Power supply
specification
voltage, current
Transmission
standard
Type of isolation
Transmission
distance
Number of occupied
I/O points
Performance
Communication
specification
method
Baud rate
Communication
format
LED display
(LED color)
4.2 Outside Dimensions and Part Names
1) Top cover
2) POWER LED
Li g h t i ng w h i le p owe r i s c o r r e c t l y
supplied.
3) RD LED
Lighting while receiving data.
4) SD LED
Lighting while sending data.
5) Extension cable
6) Direct mounting hole
7) DIN rail mounting slot
(DIN rail width :35 (1.37"))
8) DIN rail mounting clip
4.3 Terminal configuration and terminal screws
The terminal configuration of the RS-485 port on the 485ADP is as shown below.
1)
2)
3)
4)
8
)
5)
6)
7
)
Terminals screws of terminal block for RS-485 are M3 threaded. Therefore, connect wiring by fitting a
crimped terminal suited to the terminal screws (see below) to the cable.
Tightening torque of terminals is 0.5 to 0.8 N·m. Screw terminals must be secure enough to prevent a
loose connection from causing a malfunction.
6 . 2 m m
( 0 . 2 4 i n c h e s )
o r l e s s
HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100-8310
HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN
500 V AC, 1 min (Between all terminals in batch and FG terminal)
5 MΩ or more, 500 V DC by Megger
(Between all terminals in batch and FG terminal)
5 V DC (supplied from PLC main unit) max. 30 mA
24 V DC (supplied from External power supply) max. 50 mA
Conforming to RS-485/RS-422
Photo-coupler isolation
Total extension distance: 500 m or less
(50 m or less if FX
-485-BD or FX
2N
0 point (unrelated to maximum number of controlled points of the PLC)
Half-duplex
N:N network: 384000 bps, Parallel link: 19200bps
Computer link, No protocol: 300/600/1200/2400/4800/9600/19200 bps
N:N network, Parallel link
Computer (dedicated protocol: format 1/format 4), No protocol
Power: green, RD: red, SD: red
Weight:
Color:
DIN rail width: 35 mm (1.37")
Accessories: Terminal resistors (330 Ω x 2 and 110 Ω x 1),
1) 24+ terminal . . . .Power supply terminal (M3 screw)
2) 24G terminal. . . .Power supply terminal (M3 screw)
3) FG terminal . . . .Frame ground (M3 screw)
4) SDA terminal . . .Data transmission terminal (M3 screw)
5) SDB terminal . . .Data transmission terminal (M3 screw)
6) LINK SG . . . . . . .Signal ground (M3 screw)
7) RDB terminal . . .Data transmission terminal (M3 screw)
8) RDA terminal . . .Data transmission terminal (M3 screw)
M 3 t h r e a d s
Manual number : JY997D53101
Manual revision : D
Date
: September 2003
Specification
-485-BD is installed in connected equipment)
1N
2-φ4.5(0.18)
1)
2)
3)
4)
4(0.16)
43(1.69)
Approx. 0.3 kg (0.66 lbs)
Munsell 0.08GY 7.64/0.81
Station number label for linking
6 . 2 m m
( 0 . 2 4 i n c h e s )
o r l e s s
Unit : mm(inches)
5)
9(0.35)
87(3.43)
M 3 t h r e a d s
6)
7)
8)

Advertisement