SHDSDA1 OPERATION Introduction to this Operation Manual This manual covers the operation and use of the module described below. WARNING… THE FRONT PANEL OF THE UNIT MUST NOT BE OPENED BY THE OPERATOR. ACCESS IS ONLY PERMITTED FULLY QUALIFIED INSTALLATION ENGINEERS.
SHDSDA1 OPERATION Scope of this Operation Manual This is the operation manual for the System HD Single Channel Distribution Amplifier Module. It covers the modules ordered under the following codes : SHDSDA1S-S1 – Standard 8 output distribution amplifier with basic reporting.
SHDSDA1 OPERATION Features SMPTE292M 1.485Gbit/s HD-SDI data rate supported Eight equalised and reclocked HD-SDI data outputs Can equalise over 100m of cable Alarm functions for poor quality input signals and device malfunction Stand-alone or RollCall operation Incoming signal analysis available as an...
SHDSDA1 OPERATION Technical Profile INPUT RollCall™ Electrical 1.485GBit/s HD-SDI General alarm ‘Standard’ RollCall Supply voltage levels Connector Format BNC 75ohm panel jack monitoring options: Board temperature Input Cable Length 100m 800mV ± 10% Peak-to-peak CRC status ‘Enhanced’ RollCall signal amplitude...
Page 6
SHDSDA1 OPERATION Notes… 1. The eight output HD-SDI distribution amplifier (DA) is available with two levels of monitoring sophistication. standard option which provides board level information such as supply faults and minimum incoming signal analysis. The enhanced monitoring option adds...
SHDSDA1 OPERATION Rear Interface Connections Rear Interface Notation Guide Electrical HD-SDI Input A High Definition Serial Digital electrical input though a 75 Ω BNC connector is denoted in the way shown opposite. The “ H ” denotes the High Definition element and the “ n ” is the connection number for that particular rear interface.
SHDSDA1 OPERATION Rollcall Menu System When a System HD Control and Monitor board is fitted in the enclosure a range of monitoring information is available via RollCall ™ External Monitoring Description General alarm Input power fault or overcurrent trip or...
SHDSDA1 OPERATION Rollcall Monitoring Features Module Infrastructure: General Alarm Supply Voltage Levels Board Temperature Incoming Signal analysis: Input Status Line Standard Frame Type Frame Rate CRC Error analysis: CRC Error Count ...
SHDSDA1 OPERATION Manual Revision Record Date Version No. Issue No. Change Comments 16/06/01 First draft document Issued 051001 Edited current feature list Only New issue released states features that are present in current release A1.0.000 030402 New monitoring features added...