WARNING!
Before proceeding with the combustion analysis remember to set the proper fuel and analysis mode through the menu
"SET ANALYSIS", as described in the following:
Automatic,
ANALYSIS SETUP
at turn on
►Mem.:
001
Or
Fuel:
Natural gas
Oper.:
Rep.:
full
Mode:
manual
Using the menu "SET ANALYSIS" you can also set the number of memory in which the acquired data ("Memory")
are stored, as well as set the data of the operator performing the analysis ("Oper.") and finally the model of
receipt to be printed ("Rep.").
O
4.2
Eff 83.4
2
CO
9.3
Loss16.6
2
Xair 1.25
CO
146p
Tf 190.1C
Ta
15.4C
ΔT
74.7C
►RefO
2
O
4.2
Eff 83.4
2
CO
9.3
Loss16.6
2
Xair 1.25
CO
146p
Tf 190.1C
Ta
15.4C
ΔT
74.7C
►RefO
001/1:120
2
Automatically
In case the automatic print mode is set then the average analysis
printing start automatically.
Conversely, after the sampling of the third analysis, the average
analysis is shown, so that it can be sent to the printer as
explained in the following.
Note: at this stage turn on the printer (BT / IR) and place it close
to the instrument.
O
4.2
Eff 83.4
2
CO
9.3
Loss16.6
2
CO
146p
Xair 1.25
Tf 190.1C
Ta
15.4C
ΔT
74.7C
►RefO
Mem.:001/A
2
FUEL
►Natural gas
Propane
L.P.G.
Butane
Diesel oil
Only when the selected
m e m o r y
a l r e a d y
contains an analysis.
AUTOMATIC ANALYSIS
WARNING
Memory
Memory location is
Draft
already occupied
Smoke
CO amb
QUIT
DELETE
SAVE
Automatically
saves the first
Memory
sample when the
Automatically
Analysis
set interval
Model
expires, and so on
until the third
sample.
PRINT
►Print report
Memory
Print setup
Analysis
Print test
Model
PRINT
Compliant with: EN 50379-1, EN 50379-2, UNI 10845, UNI 10389-1
SAVE ANALYSIS
KEYBOARD FUNCTIONS
001/1
yes
yes
yes
QUIT
PRINT REPORT
001
average
total
Please wait ...
PRINT REPORT
001
average
total
QUIT
Features
Flue gas analysis according UNI 10389-1
Calculating of stack heat loss and efficiency
CO environment measurement
Store Smoke value, calculating mean value
Measuring differential pressure
Draught measurement according to UNI 10845
Pressure measurement in the gas supply pipe.
The magnets in the back of the instrument can damage
credit cards, hard driver, mechanical watches, pacemakers,
defibrillators and other devices proven sensitive to
magnetic fields.
It is recommended to keep the instrument at a distance of
at least 10" away from these devices.
ON / OFF
Enters the modify mode
for the selected data /
Confirms the settings
Memory Menu
Draft Menu
Analysis Menu
Configure / Info Menu
E Instruments respects the nature and the environment, therefore provides this quick user guide to
avoid any unwanted waste of paper.
However the complete manual for use and maintenance of the instrument is already available in
the USB stick (included).
Respect your environment: think before printing the full manual on paper.
402 Middletown Blvd, Suite 216, Langhorne, PA 19047 USA
Tel: (215) 750-1212; Fax: (215) 750-1399
info@E-Inst.com - www.E-Inst.com
COMPLETE MANUAL
ON USB FLASH DRIVE
Cancels the modification or
the operation / goes back to
the previous screen
Zoom on Analysis (+)
Select / Modify
Zoom on Analysis (-)
Print menu
Measurements Menu
K800000000EJ 026741 140416

Advertisement

loading

Summary of Contents for E Instruments BTU700

  • Page 1 Configure / Info Menu explained in the following. E Instruments respects the nature and the environment, therefore provides this quick user guide to Note: at this stage turn on the printer (BT / IR) and place it close avoid any unwanted waste of paper.
  • Page 2 ----- °F ticket through the "Print" menu. through the Print menu. 68.4 °F KEEP PRESSED QUIT KEEP BTU700 FOR 2 SN:00001 Ver:1.00 SECONDS AIR T AIR T Save the measurement Save the measurement. PRINT Eff 83.4...