Download Print this page

Omega CN1000-RTD Quick Start page 2

Temperature controller with time proportional control

Advertisement

12504ML-98A_CN1000-RTD_OMG.qxd
8/13/99
11:29 AM
WARRANTY/DISCLAIMER
OMEGA Engineering, Inc. warrants this unit to be free of defects in materials
and workmanship for a period of
13 months
from date of purchase. OMEGA
Warranty adds an
grace period to the normal
additional one (1) month
one (1)
year
product warranty to cover handling and shipping time. This ensures that
OMEGAÕs customers receive maximum coverage on each product.
If the unit should malfunction, it must be returned to the factory for evaluation.
OMEGAÕs Customer Service Department will issue an Authorized Return (AR)
number immediately upon phone or written request. Upon examination by
OMEGA, if the unit is found to be defective it will be repaired or replaced at no
charge. Omega's WARRANTY does not apply to defects resulting from any
action of the purchaser, including but not limited to mishandling, improper
interfacing, operation outside of design limits, improper repair, or unauthorized
modification. This WARRANTY is VOID if the unit shows evidence of having
been tampered with or shows evidence of being damaged as a result of
excessive corrosion; or current, heat, moisture or vibration; improper
specification; misapplication; misuse or other operating conditions outside of
OMEGAÕs control. Components which wear are not warranted, including but
not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various
products. However, OMEGA neither assumes responsibility for any
omissions or errors nor assumes liability for any damages that result
from the use if its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA warrants only that the parts
manufactured by it will be as specified and free of defects. OMEGA
MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY
KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies
of purchaser set forth herein are exclusive and the total liability of
OMEGA with respect to this order, whether based on contract,
warranty, negligence, indemnification, strict liability or otherwise, shall
not exceed the purchase price of the component upon which liability is
based. In no event shall OMEGA be liable for consequential, incidental
or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor
shall it be used: (1) as a ÒBasic ComponentÓ under 10 CFR 21 (NRC), used in
or with any nuclear installation or activity; or (2) in medical applications or
used on humans. Should any Product(s) be used in or with any nuclear
installation or activity, medical application, used on humans, or misused in any
way, OMEGA assumes no responsibility as set forth in our basic WARRANTY
/ DISCLAIMER language, and additionally, purchaser will indemnify OMEGA
and hold OMEGA harmless from any liability or damage whatsoever arising
out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service
Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA,
PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER
FROM OMEGAÕS CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on
the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper
packaging to prevent breakage in transit.
FOR WARRANTY RETURNS,
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair
please have the following information
available BEFORE
charges. Have the following
information available BEFORE
contacting OMEGA:
contacting OMEGA:
1. P.O. number under which the
1. P.O. number to cover the COST of
product was PURCHASED,
2. Model and serial number of the
the repair,
2. Model and serial number of product,
product under warranty, and
3. Repair instructions and/or specific
and
3. Repair instructions and/or specific
problems relative to the product.
problems relative to the product.
OMEGAÕs policy is to make running changes, not model changes, whenever an
improvement is possible. This affords our customers the latest in technology and
engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved.
This document may not be copied, photocopied, reproduced, translated, or
reduced to any electronic medium or machine-readable form, in whole or in
part, without prior written consent of OMEGA ENGINEERING, INC.
PATENT NOTICE: The ÒMeter Case Bezel DesignÓ is a trademark of
NEWPORT Electronics, Inc., registered in the U.S. USED UNDER LICENSE.
This product is covered by one or more of the following patents: U.S. Pat. No.
Des. 336,895; 5,274,577 / CANADA 2052599; 2052600 / ITALY 1249456;
1250938 / FRANCE BREVET No. 91 12756 / SPAIN 2039150; 2048066 /
UK PATENT No. GB2 249 837; GB2 248 954 / GERMANY DE 41 34398 C2.
OTHER INTERNATIONAL PATENTS PENDING.
MQS1609/0899
12504ML-98 Rev. A
Page 2
5
To Set the Decimal Point Position:
1.
If it's not already shown, press
MENU until the meter shows:
SETPTS
/MAX
/DEV
MENU
RESET
2.
Press
/DEV. The meter
displays:
SETPTS
/MAX
/DEV
MENU
RESET
3.
Press
/MAX to move the
decimal point to the desired
location. Choices are: FFFF.
or FFF.F.
SETPTS
/MAX
/DEV
MENU
RESET
4.
Press MENU to select the decimal point position
shown. The meter displays:
SETPTS
/MAX
/DEV
MENU
RESET
SETPTS
/MAX
/DEV
MENU
RESET
To Select the Temperature Unit
(Fahrenheit or Celsius):
1.
If it's not already shown, press
MENU until the meter shows:
SETPTS
/MAX
/DEV
MENU
RESET
2.
Press
/DEV. The meter
displays:
/MAX
SETPTS
/DEV
MENU
RESET
3.
Press
/MAX to display the
setting you want. Choices are
F and C.
/MAX
SETPTS
/DEV
MENU
RESET
4.
Press MENU to select the temperature meter
shown.
The
meter
displays:
/MAX
/MAX
SETPTS
/DEV
MENU
RESET
SETPTS
/DEV
MENU
RESET
6
Begin Operation
Reinitialize the meter (press
RESET twice or press MENU
until RST flashes on the display).
SETPTS
/MAX
/DEV
MENU
RESET
When the temperature appears,
the meter is up and running.
Changing Setpoint Values:
1.
While in RUN mode, press SETPTS. The unit
displays setpoint 1:
SETPTS
/MAX
/DEV
MENU
RESET
SETPTS
/MAX
/DEV
MENU
RESET
You can change setpoint 1 or press SETPTS
again to show the current value for setpoint 2.
2.
To change the setpoint 1 value:
¥
Press
/DEV until the digit(s) you want to
change flashes on the display.
¥
Press
/MAX to change the value.
¥
Press SETPTS to store the value shown. The
current value for setpoint 2 is shown:
SETPTS
/MAX
/DEV
MENU
RESET
SETPTS
/MAX
/DEV
MENU
RESET
3.
When setpoint 2 appears, you can change it using
the procedure above or press SETPTS to return
to RUN mode.
WARNING: These products are not designed for use in, and should not be used
for, patient connected applications.
This device is marked with the international caution symbol. It is important
to read the Setup Guide before installing or commissioning this device as
it contains important information relating to safety and EMC.
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its products to
the European New Approach Directives. OMEGA will add the mark to every
appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA
Engineering, Inc. accepts no liability for any errors it contains, and reserves the right
to alter specifications without notice.
omega.com
TRADEMARK NOTICE:
, and
are
trademarks of OMEGA Engineering, Inc.
QUICK START
RoHS 2 Compliant
CN1000-RTD
TEMPERATURE CONTROLLER WITH
TIME PROPORTIONAL CONTROL
OMEGAnet¨ On-Line Service
Internet e-mail
http://www.omega.com
info@omega.com
Servicing North America:
USA:
One Omega Drive, P.O. Box 4047
Stamford, CT 06907-0047
ISO 9001 Certified
Tel: (203) 359-1660
FAX: (203) 359-7700
e-mail: info@omega.com
Canada:
976 Bergar
Laval (Quebec) H7L 5A1
Tel: (514) 856-6928
FAX: (514) 856-6886
e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada:
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BEST
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico
TEL: (001)800-826-6342
FAX: (001) 203-359-7807
En Espa–ol: (001) 203-359-7803
e-mail: info@omega.com.mx
Servicing Europe:
Benelux:
Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: +31 (0)20 6418405
FAX: +31 (0)20 6434643
Toll Free in Benelux: 0800 0993344
e-mail: nl@omega.com
Czech Republic:
RudŽ arm‡dy 1868, 733 01 Karvin‡ 8
Tel: +420 (0)69 6311899
FAX: +420 (0)69 6311114
e-mail: czech@omega.com
France:
9, rue Denis Papin, 78190 Trappes
Tel: +33 (0)130 621 400
FAX: +33 (0)130 699 120
Toll Free in France: 0800406342
e-mail: france@omega.com
Germany/Austria:
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel: +49 (0)7056 9398-0
FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 TC-OMEGA
SM
e-mail: germany@omega.com
United Kingdom:
One Omega Drive,
ISO 9002 Certified
River Bend Technology Centre
Northbank, Irlam
Manchester M44 5EX United Kingdom
Tel: +44 (0)161 777 6611
FAX: +44 (0)161 777 6622
Toll Free in United Kingdom: 0800 488 488
e-mail: sales@omega.co.uk
®
,
¨
¨
¨

Advertisement

loading