1.
Ensure the heater is connected to the proper source of gas and proper
inlet pressures are supplied. The heater must be installed by a
qualified installer.
2.
Set thermostat knob (green button) to high position. Rotate the control
knob (black) counter clockwise to 'PILOT' position. Depress and hold
control knob.
3.
Light the pilot burner using a long reach lighter through lighting hole
provided.
Release the knob after 60 seconds. Pilot will remain lit. Main burner
will remain off.
4.
Turn control knob counterclockwise to 'ON' position. Main burner
will light.
5.
If the main burner fails to light, turn the control knob clockwise to the
'OFF' position, wait 5 minutes and repeat step 3.
6.
The green knob controls the thermostat option. This will light and
extinguish the main burner as the temperature fluctuates.
1.
Turn the control knob clockwise to the 'OFF' position. Both main
burner and pilot burners will extinguish.
2.
Turn off source of fuel.
LIGHTING INSTRUCTIONS
SHUT OFF INSTRUCTIONS