Download Print this page

Honeywell GSMV4G Quick Installation Manual page 2

Gsm communicators

Advertisement

4. Connect and Route the Audio Cable for Two-way Voice (if used)
The communicator requires an optional audio cable (GSMV-AUDIO, grey) to support two-way
voice using an AVS Base Unit. Note the AVS Base Unit is part of Honeywell's AVS Audio
Verification System. This system consist of the AVS Base Unit, Remote Station, and the
Remote Station PC board. For detailed information, please refer to the AVS Audio Verification
System documentation. Follow the guidelines below for connecting the audio cable.
1. Power down the communicator, control panel and AVS Audio Verification System. (When
the communicator is fully wired up, restore power to the control panel and AVS Audio
Verification System.)
2. Connect one end of the audio cable to the audio connector located on the small PC board.
3. Route the audio cable to the connector on the AVS Base Unit and connect the cable.
4. Ensure the audio cable ends are secured with tie wraps to reduce strain.
5. Setup the Account, Activate the SIM, Program, and Register the Communicator
SETUP THE ACCOUNT
To setup the customer account you will need to contact the central monitoring station to get
account information, and have access to the AlarmNet Direct website. To access the AlarmNet
Direct website visit – https://services.alarmnet.com/AlarmNetDirect
If you do not wish to use the AlarmNet Direct website, you may call AlarmNet to setup the
account; just phone 800-222-6525, then select option 1.
(Monday–Friday 8:00 am to 9:00 pm, Saturday 9:00 am to 5:30 pm EST)
Have the following information ready:
Primary City ID (two digits),
obtained from your monitoring
station.
Primary Central Station ID (two
digits), obtained from your
monitoring station.
ACTIVATE THE SIM
Note: The communicator comes with a SIM (Subscriber Identity Module) that needs to
be activated. The GSMVCN4G and IGSMVCN4G come already activated.
To activate the SIM, log into the AlarmNet Direct website. (Refer to the online help if needed.)
Enter the required information, then activate the SIM.
PROGRAM THE COMMUNICATOR
Using the AlarmNet Direct website:
Log in as you did to activate the SIM and complete the communicator programming using the
"Program New Device GSM/I" tool. (Refer to the online help if needed.)
When complete you may log out of the AlarmNet Direct website.
Note: If all LEDs FAST BLINK in unison with the RSSI LEDs this
indicates a Hardware Error.
ON – NOT registered with AlarmNet.
GRN
OFF – Registered with AlarmNet.
FAST BLINK – Download session with Compass in progress.
SLOW BLINK – In unison with yellow LED, registration in progress.
ON – Message transmission pending.
YEL
QUICK PERIODIC BLINK – Normal.
FAST BLINK – Message waiting for network ACK.
SLOW BLINK – Idle power abnormal.
SLOW BLINK – In unison with green LED, registration in progress.
ON – No contact with network.
RED
OFF – Normal.
SLOW BLINK – Loss of communication with the panel (ECP fault).
FAST BLINK – No network contact AND loss of communication with the panel.
TB 1
1
2
3
4
5
6
7
8
TAMPER
9
SWITCH
10
11
1
IGSMV4G-010-V0
Ê800-11796oŠ
800-11796 5/12 Rev. B
Primary Subscriber ID (four digits), obtained from
your monitoring station.
Communicator's MAC ID, and MAC CRC number is
located on the box and inside the communicator.
FACTORY
USE ONLY
TECH SUPPORT
USE ONLY
2 Corporate Center Drive, Suite 100, P.O. Box 9040, Melville, NY 11747
Copyright  2012 Honeywell International Inc.
TB 1
1
2
3
4
5
6
7
8
9
10
11
Using the 7720 Programming Tool:
Ensure the system is powered up and connect the programming tool to the communicator. Accept all
default settings except the following prompts which need to be answered. Then exit the programming
mode.
Device Mode ECP
Primary City ID (??)
Primary CS ID (??)
Primary Sub ID (????)
Device Address (03)
The following prompt appears for the IGSMV4G and IGSMVCN4G only.
Notify Panel of Neither
Fault
REGISTER THE COMMUNICATOR
Registering the communicator activates the account with AlarmNet and enables the control panel to
send reports. There are three ways to register the communicator:
• You can register by logging into AlarmNet Direct choosing "Show Programmed Devices GSM/I"
tool. Search for the account using the Account Information or MAC ID. Under the "Actions"
column, use the pulldown menu select "Register" the account.
• After the communicator is installed and programmed, you can register by clicking the Tamper
Switch 3 times.
• After the communicator is installed and programmed, you can register by using the 7720P
Programming tool. Simply: Press [Shift ] then press []. Please wait for "Registration SUCCESS"
message.
MODULE'S RECEIVED SIGNAL STRENGTH (RSSI)
When the Mode Switch is NOT depressed, LED 1 will illuminate red.
The remaining LEDs indicate RSSI (Received Signal Strength).
MODULE'S OPERATION MODE
When the Mode Switch IS depressed, LED 1 will be OFF.
LEDs 2 and 3 indicate the module's communication mode with the control panel.
Mode
ECP
Zone
4204
2 - 4204
MODULE'S STATUS
RSSI / MODE
When the Mode Switch IS depressed, LED 1 will be OFF.
AND
LEDs 4, 5, and 6 indicate the module's Status.
STATUS LEDs
LED 4 (green)
ON - Connected to
Internet.
OFF - Not connected
to Internet.
Note: This LED is
functional on the
internet models
only.
MODE
SWITCH
ON – Ethernet Link detected.
Ethernet Link/Activity
OFF – No link detected.
GREEN
FAST BLINK – Transmitting/Receiving Data.
Link Speed
ON – 100 MB/S link to Internet.
OFF – 10 MB/S link to Internet.
GREEN
Network Collision
BLINKING – Network collision detected.
OFF – Normal.
YELLOW
www.honeywell.com/security
AVS BASE UNIT
1
2
3
4
1
2
3
4
5
Press [#].
Enter number 01-99, then press [#].
Enter number 01-FE, then press [#].
Enter number 0001-9999, then press [#].
Accept the default by pressing [#], or change if this address
is already used.
Press [] to scroll, choose Notify Panel of Both IP&GSM
Flts, then press [#].
LED 2 (yellow)
LED 3 (yellow)
OFF
ON
OFF
ON
LED 5 (green)
LED 6 (green)
ON - GPRS service
ON - Module registered, no second
available.
site available.
OFF - No GPRS service
OFF - Module not registered with
available.
network carrier.
FAST BLINK - GPRS in
SLOW BLINK - Module registered,
use.
second site available, and low signal
strength.
NORMAL BLINK - Module registered,
second site available, acceptable
signal strength.
FAST BLINK - Module registered,
second site available, excellent
signal strength.
For internet models only.
WARRANTY
For the latest warranty information go to:
http://www.security.honeywell.com/hsc/resources/wa/
OFF
OFF
ON
ON

Advertisement

loading

This manual is also suitable for:

Gsmvcn4gIgsmv4gIgsmvcn4g