Mounting Thermostat - Honeywell T8611G Chronotherm Installation Instructions Manual

Deluxe zoning heat pump thermostat
Table of Contents

Advertisement

Fig. 4. Typical wiring diagram for T8611G on TotalZone® Control Panel.
FOR WRAPAROUND
INSERTION STRIP
7/16 IN. (11 MM).
Fig. 5. Correct wiring technique.

Mounting Thermostat

1. Engage tabs at the top of the thermostat and wall-
plate. See Fig. 6. Be sure to align subbase pins to
avoid damage to the thermostat.
2. Press lower edge of case to close and latch.
NOTE: To remove the thermostat from the wall, first pull
out at the bottom of the thermostat; remove top
last.
T8611G CHRONOTHERM
1
C
R
E
Y
NORMALLY, WIRE E ON THERMOSTAT TO W1/E ON PANEL;
1
ALTERNATIVELY, INSTALL JUMPER FROM E TO Y ON
THERMOSTAT AND OMIT WIRE TO W1/E ON PANEL.
2
CONNECT O/B JUMPER ON TZ-4 PANEL WHEN O/B TERMINAL ON
THERMOSTAT IS CONFIGURED AS O.
3
CONNECT THE OC TERMINALS ONLY IF THE ZONE-A-LONE UNOCCUPIED
FEATURE IS DESIRED. SEE TZ-4 INSTALLER INSTRUCTIONS FOR EXPLANATION.
FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).
®
DELUXE ZONING HEAT PUMP THERMOSTAT
OC
OC
2
TZ-4
THERMOSTAT
CONNECTORS
G
O/B
W2
L
OT
M4826
A.
B.
Fig. 6. Mounting thermostat on wallplate.
3
3
OT
OC
OC
C7089B OUTDOOR
TEMPERATURE
SENSOR (OPTIONAL)
M20932
ENGAGE TABS
AT TOP OF
THERMOSTAT
AND WALLPLATE.
PRESS LOWER
EDGE OF CASE
TO LATCH.
M14634
69-1414—2