INSTALLER SETUP

The Installer Setup is used to customize the thermostat
to specific systems. Some of the options include
temperature display, changeover, and outdoor
temperature display. Installer Setup numbers are listed in
Table 4. The table includes all the configuration options
and the factory settings for the T8611.
Table 3. Default Program Settings.
Period
Time
Wake
6:00 AM
Leave
8:00AM
Return
5:00 PM
Sleep
10:00 PM
A combination of key presses are required to use the
Installer Setup feature:
— To enter the installer setup, press and hold the
information i key with the increase
keys until the first number is displayed. All display
segments appear for approximately three seconds
before the number is displayed. See Fig. 9 and 10.
— To advance to the next Installer Setup, press the
Time ∆ key.
— To change a setting, use the increase
decrease
key.
— To scroll the Installer Setup numbers backward, press
the Time ∇ key.
Installer Setup
Number (Press
Time ∆ key to
Select
change)
Not Used.
1 thru 4
Heating cycle
a
rate
6 (Not Used).
Not Used.
8 thru 11
System setting
adjustment
Adaptive
Intelligent
Recovery™
control.
T8611G CHRONOTHERM
Heat
Cool
Setpoint
Setpoint
70°F
78°F
Auto
(21°C)
(25.5°C)
62°F
85°F
Auto
(16.5°C)
(29.5°C)
70°F
78°F
Auto
(20°C)
(25.5°C)
62°F
82°F
Auto
(16.5°C)
(28°C)
and decrease
or
Table 4. Thermostat Installer Setup Options.
Factory Setting
Display
5
6
Stage 2
7
9
Emergency heat
12
1
13
0
Adaptive Intelligent
Recovery™
control is activated
(system starts
early so setpoint is
reached by start of
program period).
®
DELUXE ZONING HEAT PUMP THERMOSTAT
— To exit the Installer Setup, press Run Program.
Wait
Set Program
Recovery
Hold for
Filter
Em Ht
Mon
Tue Wed Thu Fri Sat Sun
Wake Leave Return Sleep
Fan
Setting
Fig. 9. Display of all LCD segments.
IMPORTANT
Only configurable numbers are shown on the
device. Review Table 4 factory-settings and
mark any desired changes in the Actual Setting
column. When Installer Setup is complete,
review the settings to confirm that they match
the system.
Description
Display
3 or 9
3 or 6
Manual
0 or 2
changeover
5
Set Day/Time
Temporary Setting
AM
PM
Aux Ht
Days
Repl Batt
Room
DST
FACTORY SETTING OR OTHER
INSTALLER SETUP
CHOICE DISPLAY (COLUMN 3
NUMBER DISPLAY
OR 5 OF TABLE 3)
(COLUMN 2 OF TABLE 3)
Fig. 10. Display of Installer Setup
number and setting.
Other Choices
(Press
or
key to change)
Description
3—3 cph (factory setting for
first stage of heat)
6—6 cph used for second
stage of heat
9—9 cph used for electric
heat
0—Auto changeover.
2—Fixed auto changeover.
1
Conventional recovery
(system starts recovery at
programmed time).
System
Em Heat
Off
Cool
Auto
Fan
Outdoor
On
Heat
Cool
Auto
M14559
M14618
Actual
Setting
69-1414—2