Figure 9: Parameter Changes In - Advantech AMT-73 Installation And Operation Manual

Amt-70 series. l-band satellite modem 32k - 40 msymbol bpsk, qpsk, oqpsk, 8psk, 16qam
Table of Contents

Advertisement

If these loop-back components are not readily available, you could use the internal IF loop-back mode
of the modem. To activate the internal IF loop-back mode, perform the following:
From the MAIN MENU, arrow to TEST, hit ENT.
With the M of MODE flashing, hit ENT
Arrow to LOOPBACK, select ON, and hit ENT.
From the MAIN MENU, arrow to RX, hit ENT.
Arrow down to INPUT, hit ENT.
Select LOOPBACK and hit ENT
This is an absolute BER test capability that provides accurate results. To review the results, perform
the following:
From the MAIN MENU (if in a different menu, hit CLR once or twice to get back to the MAIN
MENU), arrow over to MONITOR and hit ENT.
Arrow over to RX and hit ENT.
Arrow down several times until BER appears in the upper left corner of the display. It will
display unlocked while the modem is acquiring the signal.
It may be necessary to raise the power output to get the modem to acquire. To do this, perform the
following steps:
From the MAIN MENU, arrow over to TX and hit ENT.
Hit ENT when the T in TX flashes.
Arrow down (twice) until POWER = -xx dBm appears (xx should actually be -25 at this time).
Arrow over until the P in POWER is flashing. Hit ENT.
Change the power output by arrowing over to each value and then use the keypad to enter the
number. When the number is correct, hit ENT, and the new value entered will be executed.
Once the demodulator locks up, the BER readout will display the actual number of accumulated errors.
(You must be in MONITOR MAIN MENU and BER, as above.) Other estimated values, such as SNR,
Eb/No, baud (symbol) rate, AGC (labeled POWER.AGC) can be observed during this BER testing by
arrowing up or down while in the MONITOR menu.
If a different data rate, code rate, FEC type, or modulation scheme is desired, use the information from
Figure 6 to change those parameters:
TX Main Menu
PARAMETER
CURRENT
VALUE
MOD
QPSK
UNITS
BPS
CARR FRQ
1000000000Hz
DATA
005000000BPS
CODE
INTELSAT
RATE
½
RSRATE
OFF
ENTER the changed values from the TX and RX menus, then page down to RECONFIGURE =
READY, press enter and then enter again to CONFIRM.
AMT-70/AMT-73/AMT-75 Installation and Operation
Figure 9: Parameter Changes in Test Mode
DESIRED
PARAMETER
VALUE
16QAM
DEMOD
BPS
UNITS
0950000000Hz
CARR FRQ
2048000BPS
DATA
TPC16K
CODE
8/9
RATE
OFF
RSRATE
RX Main Menu
CURRENT
DESIRED
VALUE
VALUE
QPSK
16QAM
BPS
BPS
1000000000Hz
0950000000Hz
005000000BPS
2048000BPS
INTELSAT
TPC16K
1/2
8/9
OFF
OFF
58