Xinje XP3-16R Manual page 20

Xp3 series plc/hmi combined unit
Table of Contents

Advertisement

 
Note:
When activating the register's "Set", it means this component has not only a monitor function but
also a set function.
2-4-8 Text
Click
key and place it in the display area. Set its property in the property area. In industrial
control, some parameters change slowly. The operator wants to know how these parameters are
changing within a certain time. Choose the trend diagram to suit.
Range:
These values determine the trend diagram's width and height.
 Register:
PLC station: The device's address, which connects with the panel.
 Register number: Used as sequence data storage area.
 Register ID: The trend diagram's corresponding register address.
 Mode: Data format (including Decimal, HEX/BCD, signed or not).
 Register:
Full value: The register's corresponding value with the trend diagram 100% scale display.
Zero value: Used as sequence data storage area.
Zero value: Used as sequence data storage area .
Register ID: The trend diagram's corresponding register address.
Mode: Data format (including Decimal, HEX/BCD, signed or not).
XP3 PLC/HMI Hardware Manual
 
Page 20 of 42
LMAN007_R2V2