Download Print this page

Panasonic KT4R Communication Instruction Manual page 46

Temperature controller
Hide thumbs Also See for KT4R:

Advertisement

Contact No.
Read/Write
R0061
R0062
R0063
R0064
R0065
R0066
R0067
R0068
R0069
R006A
R006B
R006C
R006D
R006E
R006F
R0070
R0071
R0072
R0073
R0074
R0075
R0076
R0077
R0078
R0079
R007A
:
R009F
R/W: Both Read and Write can be executed.
R:
Read can be executed. If Write is executed, data will be discarded, and acknowledgement will be returned.
If Data larger than Contact No. R0100 is read or written, Error code 61H will be returned.
If Data larger than DT10000 is read or written, Error code 61H will be returned.
(*1) If any action is changed in [Event output EV1 allocation] or in [Event output EV2 allocation], EV1 alarm value and EV2 alarm value, etc. will
revert to factory default value.
For the items to be initialized: Refer to Section "6.6 Items to Be Initialized by Changing Settings" (p.55).
(*2) If reserved items and reserved Contact No. are read, acknowledgement will be returned (but data is 0).
If they are written, data will be discarded, and acknowledgement will be returned.
(*3) If 'Not used' items are read or written, the following data will be returned depending on the communication protocol.
For MEWTOCOL, if 'Not used' items are read, acknowledgement will be returned (but data is 0). If they are written, data will be discarded, and
acknowledgement will be returned.
For Modbus, Exception code 2 (02H) will be returned.
(*4) For Manual control MV, if the following are written, Error code 61H (MEWTOCOL) or Exception code 3 (03H, Modbus) will be returned.
• When control action is ON/OFF control, and if any items except OUT1 low limit and OUT1 high limit values are written.
• When Heating side (of Heating/Cooling control) is in ON/OFF control, and if any items - except Heating side OUT1 low limit/OUT1 high limit value,
and Cooling side OUT2 low limit/OUT2 high limit value - are written.
• When Cooling side (of Heating/Cooling control) is in ON/OFF control, and if any items - except Heating side OUT1 low limit/OUT1 high limit value,
and Cooling side OUT2 low limit/OUT2 high limit value - are written.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Contents of Data
R
EV2 output Enabled/Disabled
R
Reserved
(*2)
R
Reserved
(*2)
R
Reserved
(*2)
R
Reserved
(*2)
R
Reserved
(*2)
R
Communication function
Enabled/Disabled
R
Heating/Cooling control function
Disabled/Enabled
R
Reserved
(*2)
R
Reserved
(*2)
R
Reserved
(*2)
R
Reserved
(*2)
R
Reserved
(*2)
R
Reserved
(*2)
R
Reserved
(*2)
R
Unit model: AKT9R
R
Unit model: AKT8R
R
Reserved
(*2)
R
Unit model: AKT4R
R
Reserved
(*2)
R
Reserved
(*2)
R
OUT1 output type: Relay contact
output
R
OUT1 output type: Non-contact
voltage output (for SSR drive)
R
OUT1 output type: Direct current
output
R
OUT2 output type : Relay contact
output
R
Reserved
(*2)
:
:
R
Reserved
(*2)
Data Section
0000H : Disabled (OFF)
0001H : Enabled (ON)
Always 0000H
Always 0000H
Always 0000H
Always 0000H
Always 0000H
0000H : Disabled (OFF)
0001H : Enabled (ON)
0000H : Disabled (OFF)
0001H : Enabled (ON)
Always 0000H
Always 0000H
Always 0000H
Always 0000H
Always 0000H
Always 0000H
Always 0000H
0001H : Specified model
0001H : Specified model
Always 0000H
0001H : Specified model
Always 0000H
Always 0000H
0001H : Specified model
0001H : Specified model
0001H : Specified model
0001H : Specified model
Always 0000H
:
Always 0000H