Download Print this page

Panasonic KT4R Communication Instruction Manual page 29

Temperature controller
Hide thumbs Also See for KT4R:

Advertisement

• Response message from the slave in normal status
Slave
3.5 idle
address
characters
(01H)
1
(5) Read (Slave address 1, Multiple pieces of program pattern data)
• Request message from the master (when reading the previous program pattern data)
Slave
3.5 idle
address
characters
(01H)
1
• Response message from the slave in normal status
Slave
3.5 idle
address
characters
(01H)
1
(00C8003C000A00C800780000012C001E000A012C003C0000000000780000H)
Response message data section converts to the following.
Data Item
1000H
Step 1 SV
1001H
Step 1 time
1002H
Step 1 wait value
1003H
Step 2 SV
1004H
Step 2 time
1005H
Step 2 wait value
1006H
Step 3 SV
1007H
Step 3 time
1008H
Step 3 wait value
1009H
Step 4 SV
100AH
Step 4 time
100BH
Step 4 wait value
100CH Step 5 SV
100DH Step 5 time
100EH
Step 5 wait value
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Function
Data item
code
(10H)
(1000H)
1
2
Function
Data item
code
(03H)
(1000H)
1
2
Function
Number of
code
response bytes
(03H)
(1EH)
1
1
200
60 minutes (1:00)
10
200
120 minutes (2:00)
0
300
30 minutes (0:30)
10
300
60 minutes (1:00)
0
0
120 minutes (2:00)
0
Data
(000FH)
2
Amount of data
(000FH)
2
Data
30
Data
Data (Converted to Hexadecimal)
00C8H
003CH
000AH
00C8H
0078H
0000H
012CH
001EH
000AH
012CH
003CH
0000H
0000H
0078H
0000H
Error check
3.5 idle
CRC-16
characters
(84CDH)
2
Error check
3.5 idle
CRC-16
characters
(010EH)
2
Error check
CRC-16
(F340H)
2
3.5 idle
characters

Advertisement