Grundfos DME 2 Product Manual page 60

Dme series; dms series. digital dosing
Table of Contents

Advertisement

Accessories
Automatic vent valve
Automatic vent valve for direct fitting on the pump
discharge connection.
Valve housing material: PMMA/PVC
O-ring material:
Valve ball material:
Valve seat material:
Pump head material:
Power cable length:
Opening pressure:
Maximum flow:
Supply voltage:
Plug type:
Automatic vent valve with timer (mm)
Pump type
DME 2 to 48
DMS
60
FKM
Glass
PVDF
PP/PVDF
5 ft
145 psi (10 bar)
11.9 GPH (45 l/h)
1 x 120V, 50-60 Hz
US.
A
B
Dimensions
Voltage
A + B
M30 x 3.5
1 x 120 V, 50-60 Hz
The valve is available with and without timer.
With timer:
The valve is continuously connected to the power
supply. The opening time and opening intervals are set
on the timer.
Without timer:
The valve will open when power is supplied to the valve.
This version is ideal for operation in connection with a
dosing monitor.
Plug
With timer
US
96441084
Automatic vent valve
Product number
Without timer
96471086