    C o N T E N T S Warranty ......................i Introduction ....................... 1 Getting Started ....................1 Initial Inspection ................. 1 Battery Installation ................1 Key Pad ....................2 Connecting the Probe/Cable Assembly to the Instrument ..... 3 Run Screen ................... 4 Backlight ....................
  • Page 3 General Maintenance ............... 19 material and workmanship when purchased by rental agencies for rental purposes. Within the warranty period, YSI will repair or replace, at its sole discretion, free of Sensor Maintenance ................19 charge, any product that YSI determines to be covered by this warranty.
  • Page 4: Introduction

    I N T R o D U C T I o N Thank you for purchasing the YSI Pro30, an instrument from the YSI Professional Series product family. The Pro30 measures conductivity and temperature in water. The Pro30 features an impact resistant and waterproof (IP-67) case, a...
  • Page 5: Key Pad

    Press a third time to turn backlight off. Press and hold for 3 seconds to turn instrument off. Figure 1. Pro30 with battery cover removed. Notice battery symbols indicating polarities. Menu Use to enter the System Setup menu from the Run screen.
  • Page 6: Run Screen

    Run screen (figure 4). The first time the Description of Run screen box functions from left to right: Pro30 is turned on, it will prompt you to select a language; see the First Power on section of this manual for more information.
  • Page 7: System Setup Menu

    ‘pages’ . The current page is indicated near the bottom of the display (figure 6). When Audio is enabled, the Pro30 will beep twice to indicate stability when Auto Stable is enabled. The instrument will also beep when a key is pressed.
  • Page 8: Conductivity Units (Cond. Units)

    Highlight the ESC-Exit box and press enter to save any changes and to close the Temperature Units submenu. The Pro30 can display non-temperature compensated conductivity as well as temperature compensated Specific Conductance. If Specific Conductance is selected, the Pro30 uses the temperature and conductivity values associated with...
  • Page 9: Specific Conductance Reference Temperature

    0 to 60 minutes. Press enter to save the new shutoff time. Next, Conductance in mS/cm to TDS in g/L. The Pro30’s default value is 0.65. This highlight the ESC-Exit box and press enter to close the submenu.
  • Page 10: Resetting The System Setup Menu To Factory Default

    Calibrating one of these parameters will simultaneously To reset the Pro30 settings to factory default, press the down arrow key while in calibrate the others. YSI recommends calibrating specific conductance the System Setup menu until the Reset - box is highlighted, then press enter.
  • Page 11: Taking Measurements

    Run screen. ‘Calibration Successful’ will display for a few seconds to indicate a The Pro30 can store 50 data sets in non-volatile memory for later viewing. A successful calibration and then the instrument will return to the Run data set includes the values currently on the display, i.e.
  • Page 12: Saving Data

    The Pro30 can not communicate to a PC via a Pro Series communications saddle. Connecting the Pro30 to a communication saddle may cause erratic instrument behavior. From the Run screen, use the up or down arrow keys to highlight the Save box and press enter to save the current readings.
  • Page 13: Care, Maintenance And Storage

    Data mode after erasing one data set. The openings that allow sample access to the conductivity electrodes should be Select Erase All Data Sets and press enter to clear the Pro30 memory and return cleaned regularly. The small cleaning brush included in the Maintenance Kit is to Data mode.
  • Page 14: Sensor Storage

    System Setup menu, i.e. uS vs mS and T R o U B L E S H o o T I N G Conductivity vs. Specific Conductance. Contact YSI Tech Support. Conductivity values display Ensure the conductivity sensor is Symptom Possible Solution over or Undr on Run screen.
  • Page 15: Specifications

    S P E C I F I C A T I o N S These specifications represent typical performance and are subject to change without notice. For the latest product specification information, please visit YSI’s website at www.ysi.com or contact YSI Tech Support. Parameter Range...