Hitachi C 6U2 Handling Instructions Manual page 12

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
English
NOTE
Due to HITACHI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
Information concerning airborne noise and vibration
The measured values were determined according to
EN60745 and declared in accordance with ISO 4871.
The typical A-weighted sound power level: 101 dB (A)
The typical A-weighted sound pressure level: 90 dB (A)
Uncertainty KpA: 3 dB (A).
Wear hearing protection.
Vibration total values (triax vector sum) determined
according to EN60745.
Cutting chipboard:
Vibration emission value
2
Uncertainty K = 1.5 m/s
The declared vibration total value has been measured in
accordance with a standard test method and may be
used for comparing one tool with another.
It may also be used in a preliminary assessment of
exposure.
WARNING
The vibration emission during actual use of the
power tool can differ from the declared total value
depending on the ways in which the tool is used.
Identify safety measures to protect the operator that
are based on an estimation of exposure in the
actual conditions of use (taking account of all parts
of the operating cycle such as the times when the
tool is switched off and when it is running idle in
addition to the trigger time).
11
a
2
= 2.7 m/s
h

Advertisement