If your Inverter requires service or repair please complete the Warranty Repair Form on page 16 LATRONICS PO BOX 73 MOFFAT BEACH Q 4551 PH: 61 7 5491 6988 FAX: 61 7 5491 6792 EMAIL: technical@latronics.com WEB: www.latronics.com Copyright Latronics. Doc No M70 02/07 Version 1...
Have you disconnected the battery, then tried to turn on your Inverter? TECHNICAL SPECIFICATIONS Please call *61 7 5491 6988 or email technical@latronics.com to obtain the address of your nearest service center and your RMA Number which is WARRANTY CARD essential for efficient processing.
INSTALLATION STATEMENT OF QUALITY ASSURANCE Grid Interactive Solar Systems have become increasingly popular in recent years. These systems do not necessarily require batteries for storage and The whole of the supplies have been subjected to the Quality therefore can have a very simple configuration. System Requirements in accordance with the conditions of AS/NZS ISO 9002: 1994.
Inverter Isolation and Safety Solar Input ON Solar Input ON Grid Fault Grid Fault All Latronics Inverters have an isolation rating of 3500V between AC Overload Overload and DC via the Toroidal Transformer, which ensures extremely safe Wall Mount Enclosure...
Page 6
(at Latronics option) to the replacement or repair of the goods or of acquiring equivalent goods or the cost of replacing or repairing the goods or of acquiring equivalent goods. Latronics shall not be liable in any way whatsoever for indirect or consequential loss or damage whatsoever (whether...
AM radio and in unusual cases may interfere with TV reception. The active and neutral of the AC output are electrically isolated Over the years Latronics has continued to invest significant time and effort in from the battery negative, battery positive, and earth connections.
SPECIAL FEATURES FAULT FINDING Should the Inverter appear to be malfunctioning we suggest the following to Circuit Breakers eliminate any external problems. There are 3 breakers, DC positive , DC negative & AC grid. Note: Both DC breakers need to be turned ON to activate the Inverter. The Turn the Inverter OFF by switching the DC &...
SOLAR INPUT CONFIGURATION DIP SWITCH SETTINGS Switch 1 -MPPT / Battery mode PVE 1200 In the ON position (default) the Maximum Power Point Tracking is enabled. This is required when the DC input is Photovoltaic Solar Modules only. No. of Strings...
INVERTER OPERATION Indicator Lamps When the Inverter is switched on all 4 LED'S light up for 1 second while the The 4 lights on the front panel indicate the microprocessor performs a start up and system check procedure. Inverter power level in increments of 25% LED 4 -100% (top Led).