Omron H7CZ Instruction Manual

Omron H7CZ Instruction Manual

Digital counter
Hide thumbs Also See for H7CZ:

Advertisement

Quick Links

H7CZ
Digital Counter
INSTRUCTION MANUAL
EN
Thank you for purchasing the OMRON Product.
To ensure the safe application of the Product, read this
manual carefully before using the Product and always keep
it close at hand when the Product is in use.
OMRON Corporation
©All Rights Reserved
1148606-6A
For details, refer to the latest datasheet (Cat. No. M079).
Suitability for Use
OMRON shall not be responsible for conformity with any
standards, codes, or regulations that apply to the combination
of the products in the customer's application or use of the
product.
Take all necessary steps to determine the suitability of the
product for the systems, machines, and equipment with which
it will be used. Know and observe all prohibitions of use
applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION
INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE
HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of
Liability.
Mounting and Panel-cutout Dimensions Diagram
Mounting Dimenions
Flush Mounting
(Unit: mm)
H7CZ-L8@
Y92F-30
Front panel dimensions are
Y92S-29
(order
(order
separately)
the same for all models.
separately)
Flush
Waterproof
Mounting
Packing
Panel
Adapter
(51)
7.5
84.8
48
Surface Mounting
H7CZ
-L8@
90
92.3*
P2CF-08(-E)
Front-connecting Socket
(order separately)
*These dimensions vary with
the type of DIN track
(reference value).
Operating Procedures
Parameters are set with the operation keys on the front panel.
Note: Refer to the datasheet (Cat. No. M079) for detailed parameter settings.
● Change from RUN Mode to Function Setting Mode.
● Set the parameters using the U Key.
The characters displayed in reverse video are the default settings.
Display
Parameter name
Set value
cntm
up, down
Input mode
outm
n, f, c, r, k-1, p, q, aK*1
Output mode
otim
Output time
0.01 to
0.50
to 99.99
cnts
30hz, 5khzK*1
Counting speed
iflt
Reset input signal width
20ms, 1msK*1
dp
Decimal point position
------, -----.-,
----.--, ---.--- *1
pscl
Prescale value
0.001 to
1.000
sl-h
1 to
999999
Set value upper limit
kypt
Key protect level
kp-1, kp-2, kp-3, kp-4,
kp-5, kp-6, kp-7K*1
on-a
Output ON count
0
to 9999
alarm set value
on-c
Output ON count
---
monitor value
*1: After reaching the last set value, the U Key will return to the first set value.
Displays and Settings in Run Mode
1234
Present value
Set value
2345
SET
SAFETY PRECAUTIONS
Keys to Warning Symbols
Indicates a potentially hazardous situation which, if
CAUTION
not avoided, is likely to result in minor or moderate
injury or in property damage.
CAUTION
Do not allow pieces of metal, wire clippings, or fine metallic
shavings or fillings from installation to enter the product.
Doing so may occasionally result in electric shock, fire, or
malfunction.
Minor injury due to explosion may occasionally occur. Do not
use the Counter where subject to flammable or explosive
gas.
Fire may occasionally occur. Tighten the terminal screws to
the rated torque.
P2CF Socket terminals: 4.4 lb-in (0.5 N⋅m)
Minor injury due to electric shock may occasionally occur. Do
not touch any of the terminals while power is being supplied.
Be sure to mount the terminal cover after wiring.
The life expectancy of the output relay varies considerably
according to its usage. Use the output relay within its rated
load and electrical life expectancy. If the output relay is used
beyond its life expectancy, its contacts may become fused or
there may be a risk of fire. Also, be sure that the load current
does not exceed the rated load current and when using a
heater, be sure to use a thermal switch in the load circuit.
Minor electric shock, fire, or malfunction may occasionally
occur. Do not disassemble, modify, or repair the Counter or
touch internal components.
Power supply voltage
• Panel-cutout Dimensions Diagram
(Unit: mm)
Standard panel cutout is shown in
the following diagram (conforms
P3G-08
Allowable voltage
to DIN 43700). A space of 15 mm
(order
fluctuation range
separately)
or greater (a panel cut-out
Back-
distance of 60 mm or greater) is
Power consumption
connecting
rec-ommended towards the
Socket
Adapter's hookside to enable
easier mounting work.
Operating temperature
range
Storage temperature
range
Operating humidity
48
range
Altitude
Recommended fuse
1. The thickness of a mounting
Weight
panel shouldbe 1 to 5 mm.
Installation
2. It is possible to mount Timers
environment
side-by-side. (But only towards
the non-hook side.)
n Units mounted
side-by-side
A
+1
A=(48n−2.5)
Display Section
−0
3. If the products are mounted side
1. Key Protect Indicator
by side, water resistance will be
2. Control Output Indicator
lost.
3. Reset Indicator
(Lit when the reset input or
Package Contents
Reset Key is ON.)
4. Present Value (Main
• Digital Counter
Display)
• Instruction manual (this document)
(Character height: 10 mm)
5. Set Value Display
(Sub-display)
(Character height: 6 mm)
MODE
3 s min.
Function
Power ON
Run mode
setting mode
MODE
3 s min.
Comments
---
---
Displayed only when the output mode is
c, r, k-1, p, q, or a. Unit: second
---
---
---
to 99.999
---
---
---
× 1,000
The monitor value is only displayed.
It cannot be set. × 1,000
Precautions for Safe Use
1) When mounting the Counter to a panel, tighten the two mounting screws
alternately, a little at a time, so as to keep them at an equal tightness. If the
panel screws are tightened unequally, water may enter the panel.
2) Store the Counter at the specified temperature. If the Counter has been stored
at a temperature of less than −10°C, allow the Counter to stand at room
temperature for at least 3 hours before use.
3) Mounting the Counter side-by-side may reduce the life expectancies of internal
components.
4) Use the Counter within the specified ranges for the ambient operating
temperature and humidity.
5) Do not use in the following locations:
• Locations subject to sudden or extreme changes in temperature.
• Locations where high humidity may result in condensation.
• Locations with excessive vibration or shock.
• Locations subject to water.
• Locations subject to oil.
6) Do not use the Counter outside of the rated ranges for vibration, shock, water
exposure, and oil exposure.
7) Do not use this Counter in dusty environments, in locations where corrosive gasses
are present, or in locations subject to direct sunlight.
8) Install the Counter well away from any sources of static electricity, such as pipes
transporting molding materials, powders, or liquids.
9) Internal elements may be destroyed if a voltage outside the rated voltage range
is applied.
10) Separate the Counter from sources of noise, such as devices with input signals
from power lines carrying noise, and wiring for I/O signals.
11) Do not connect more than two crimp terminals to the same terminal.
12) Up to two wires of the same size and type can be inserted into a single terminals.
13) Use the specified wires for wiring. Applicable Wires: AWG 18 to AWG 22, solid
or twisted, copper
14) Install a switch or circuit breaker that allows the operator to immediately turn
OFF the power, and label it to clearly indicate its function.
15) Approximately 14 V is output from the input terminals. Use a sensor that
contains a diode.
16) Use a switch, relay, or other contact so that the rated power supply voltage will
be reached within 0.1 seconds. If the power supply voltage is not reached
quickly enough, the Counter may malfunction or outputs may be unstable.
17) Use a switch, relay, or other contact to turn the power supply OFF
instantaneously. Outputs may malfunction and memory errors may occur if the
power supply voltage is decreased gradually.
18) When changing the set value during operation, because the H7CZ uses a
constant read-in system, output will turn ON if the set value is equal to the
present value.
19) If the set value and present value are both 0, the output will turn ON for the
default setting. The output will turn OFF during a reset operation.
20) Do not use organic solvents (such as paint thinners or benzine), strong alkali, or
strong acids. They will damage the external finish.
21) Confirm that indications are working normally, including the LCD. The indicator
LCD and resin parts may deteriorate more quickly depending on the application
environment, preventing normal indications. Periodic inspection and
replacement are required.
22) The waterproof packing may deteriorate, shrink, or harden depending on the
application environment. Periodic inspection and replacement are required.
Ratings (Specifications)
- 100 to 240 VAC, 50/60 Hz
Input method
(H7CZ-L8)
No-voltage input
ON impedance: 1 kΩ max. (Leakage
- 12 to 24 VDC/24 VAC, 50/60 Hz
current: 12 mA when 0 Ω)
(H7CZ-L8D1)
ON residual voltage: 3 V max.
85% to 110% of rated supply voltage
OFF impedance: 100 kΩ min.
(12 to 24 VDC: 90% to 110%)
Control output
Approx. 9.4 VA at 100 to 240 VAC,
Contact Output
250 VAC, 3 A (resistive load)
Approx. 7.2 VA/4.7 W at 24 VAC/12
30 VDC, 3 A (resistive load)
to 24 VDC
Electrical life of relay
100,000 operations (at an ambient
−10 to 55°C (−10 to 50°C if Counters
temperature of 23°C)
are mounted side by side)
Mechanical life of
10,000,000 operations (at an ambient
(with no icing or condensation)
relay
temperature of 23°C)
−25 to 70°C (with no icing or
External power supply
12 VDC, 100 mA
condensation)
Degreenof protection
IEC IP66, UL508 Type 4X*
25% to 85%
*
Individual mounting: Degree of protection on the front
2,000 m max.
panel of the Counter conforms to UL 508 Type 4X when all
of the following conditions are satisfied:
T2A, 250VAC,time-lag,low-breaking
The Y92S-29 waterproof packing and Y92F-30 mounting
capacity
adapter are used with the Counter. Use only these parts
Approx. 100 g (main unit only)
for replacement.
Over-voltage category II, pollution
The Counter is mounted on the flat surface of an
degree 2. (IEC 61010-1)
enclosure that is rated and marked "Type 4X for Indoor
Use Only."
Nomenclature
1
2
3
6
7
6th digit
1st digit
Terminal Arrangement
Wire properly after checking the specifications of the power supply voltage.
Internal circuit
Count
Reset
OV
(−)
(+)
Input Connections
No-voltage Inputs (NPN Inputs)
Open Collector
Voltage Output
PLC or
Sensor
sensor
Note: Operate with transistor ON
Note: Operate with transistor ON
Precautions for Correct Use
1) H7CZ models with a 12 to 24-VDC power supply use a transformer-
free power supply method in which the power supply terminals are not
isolated from the signal input terminals. If a non-isolating DC power
supply is used, unwanted current paths may occasionally burn or
destroy internal components depending on the wiring. Always check
the wiring sufficiently before use.
2) An inrush current of approx. 10 A will flow for a short time when the
power supply is turned ON. If the capacity of the power supply is not
sufficient, the Counter may not start. Be sure to use a power supply
with sufficient capacity.
3) Maintain voltage fluctuations in the power supply within the specified
operating voltage range.
4) To allow for the startup time of peripheral devices (e.g., sensors), start
Counter timing operation 200 ms to 290 ms after turning ON the
power. The input signal will not be accepted before 200 to 290 ms has
elapsed.
5) The input signal will not be accepted after 5 to 1005 ms has elapsed
from when the power supply is turned OFF.
6) Inrush current generated by turning ON or OFF the power supply may
deteriorate contacts on the power supply circuit. Turn ON or OFF to a
device with the rated current of more than 10 A.
7) The capacity of the external power supply is
100 mA at 12 V. When using a 24 VAC/12 to
24 VDC power supply, reduce the load with the
power supply voltage, as shown in the diagram
(DC power supplies only) on the right.
8) If the prescale value setting is incorrect, a
counting error will occur. Check that the
settings are correct before using this function.
9) Make sure that all settings are appropriate for the application.
Unexpected operation resulting in property damage or accidents may
occur if the settings are not appropriate.
10) Do not leave the Counter for long periods at a high temperature with
output current in the ON state. Doing so may result in the premature
deterioration of internal components (e.g., electrolytic capacitors).
11) EEPROM is used as memory when the power is interrupted. The write
life of the EEPROM is 100,000 writes. The EEPROM is written when
the power is turned OFF or when switching from function setting mode
to run mode.
12) Dispose of the product according to local ordinances as they apply.
Conformance to EN/IEC Standards
• When conforming to EMC standards, refer to the information
provided in this Instruction Manual for cable selection and other
conditions.
• This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take
adequate measures to reduce interference.
• Basic insulation is provided between power supply and input
terminals, between power supply and output terminals, and
between input and output terminals. (No insulation is provided
between the power supply and input terminals for the
H7CZ-L8D1.)
• Basic insulation is provided between power supply and output
terminals, and between input and output terminals. When double
insulation or reinforced insulation is required, apply double
insulation or reinforced insulation as defined in IEC 60664 that is
suitable for the maximum operating voltage with clearances or
solid insulation.
• Connect the input and output terminals to devices that do not have
any exposed charged parts.
Precautions for Compliance with UL Standards and CSA Standards
Notice to Users of the H7CZ in the USA and Canada
Please use the following installation information instead of the
general information in the instruction manuals in order to use the
product under certified conditions of UL and CSA when the product
is installed in the USA or Canada. These conditions are required
by NFPA 70, National Electrical Code in the USA and the
Operation Key
Canadian Electrical Code, Part I in Canada and may vary from
6. Mode Key
information given in the product manuals or safety precautions.
(Changes modes and
• Installation in a Panel
setting items)
H7CZ is normally installed on a flat surface in an operation
4
7. Reset Key
panel. Use a Type 1 Enclosure for the operation panel.
• Use the isolated source for Inputs.
8. Up Keys
1
to
6
• Environment
5
Surrounding Air Temperature: −10 to 40°C
• Accessories (Order Separately)
Track Mounting/
8
Front Connecting Socket
Flush Mounting Adapter
Waterproof Packing
Key-protect Switch Settings
When the key-protect switch
is ON, individual key
operations can be disabled
to prevent setting errors
according to the key protect
levels (KP-1 to KP-7)
shown in the following table.
* Key protect levels are set in
function setting mode.
*
Mode
Level
change
Contact Output
KP-1
Invalid
(default setting)
KP-2
Invalid
KP-3
Invalid
KP-4
Invalid
KP-5
Invalid
KP-6
Invalid
KP-7
Invalid
* Changing mode to function setting mode.
Self-diagnostic Functions
The following displays will appear if an error occurs.
Main
Sub-
display
display
No
Present value
-----
change
underflow * 2
*3
Contact Input
e1
Not lit
CPU error
Memory error
e2
Not lit
(RAM)
Memory error
e2
sum
(EEPROM) *1
No
Output Counter
e3 * 5
change
Overflow
*1. This includes times when the life of the EEPROM has expired.
Note: Operate with relay ON
*2. This occurs if the present value falls below –99999.
*3. Display flashes.(1-second cycles)
*4. The total ON count will not be cleared by using the Reset Key.
*5. The normal display and e3 will appear alternately.
When the Reset Key is pressed, e3 will not be displayed even if the
alarm set value is exceeded. (Monitoring is possible, however,
because the Counter will continue without the output ON count being
cleared.)
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp, The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC (U.S.A.)
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD. (SINGAPORE)
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
100
Load
current
(mA)
20
0
10.8
15
Power supply voltage (VDC)
8-pin
P2CF-08
8-pin, finger-safe type
P2CF-08-E
---
Y92F-30
---
Y92S-29
ON(enable)
OFF(disable)
(Factory setting)
Key protect indicator
Display switch
Reset
Up Key
in the run mode
Key
Valid
Valid
Valid
Valid
Invalid
Valid
Valid
Valid
Invalid
Valid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Valid
Valid
Invalid
Invalid
Valid
Output
Correction
Set value
Description
status
method
after reset
Either press the
No
No
Reset Key or
change
change
turn ON reset input.
Turn ON the
No
OFF
power again.
change
Reset Key
Turn ON the
No
OFF
power again.
change
Factory
OFF
Reset Key
setting.
No
No
Reset Key *4
change
change

Advertisement

loading

Summary of Contents for Omron H7CZ

  • Page 1 Keys to Warning Symbols 1) When mounting the Counter to a panel, tighten the two mounting screws 1) H7CZ models with a 12 to 24-VDC power supply use a transformer- H7CZ alternately, a little at a time, so as to keep them at an equal tightness. If the free power supply method in which the power supply terminals are not panel screws are tightened unequally, water may enter the panel.