  • Page 1 Model E200 3-Axis RF Field Strength Meter...
  • Page 2: Table Of Contents

    Table of Contents AXIS RF METER QUICK START GUIDE ..........4 INTRODUCTION ................5 The E200 Features ..............5 E201 Applications ..............6 SAFETY SUMMARY ................. 7 EMF SAFETY ..................8 COMPLIANCE STATEMENTS ............9 PRODUCT CONTENTS AND INSPECTION ........9 DEVICE DESCRIPTION ..............
  • Page 3 General Specifications ............. 29 12.2 Electrical specifications ............30 12.3 Units of Measurement ............. 31 12.4 Result modes ................31 SERVICE, REPAIRS, CALIBRATION ..........32 LIMITED TWO-YEAR WARRANTY ..........34 anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 4: Axis Rf Meter Quick Start Guide

    (we recommend using mV/m… and we recommend a maximum level of 614 mV/m for prolonged exposure). You are now ready to make your first measurements! anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 5: Introduction

    Introduction Thank you for purchasing an E200 3-Axix RF Field Strength Meter from Anaheim Scientific. This meter is designed for measuring and monitoring Radio– Frequency electromagnetic field strength. The meter is calibrated precisely over the frequency range of 50Mz~3.5 GHZ.
  • Page 6: E201 Applications

    • Wireless LAN (Wi-Fi) detection, installation. • Spy camera, wireless bug finder. • Cellular /Cordless phone radiation safety level. • Microwave oven leakage detection. • Personal living environment EMF safety. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 7: Safety Summary

    Never use a wet cloth, solvents or water, etc. • Weather conditions outside the specified limits and improper handling may adversely affect the accuracy and function of the meter. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 8: Emf Safety

    Before using field strength measuring devices, you should thus be certain that all field components to be measured lie in the specified frequency range of the measuring device. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 9: Compliance Statements

    If damage to the instrument is evident, a description of the damage should be noted on the carrier’s receipt and signed by the driver or carrier agent. Save all shipping packaging for inspection. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 10 Use of the original packing is essential. After the mechanical inspection, verify the contents of the shipment. The items included in this package are: • E200 Meter • User manual • 9V battery • Carrying case anaheimscientific.com...
  • Page 11: Device Description

    6. UNIT / ENTER switch Button 7. Hold / ALARM On/Off / Up Button 8. Backlight/Set 9. XYZ / MEM / Down Button 10. Tripod Mounting Screw 11. Battery Cover anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 12: Lcd Description

    8. X.Y.Z unit 19. CAL symbol 9. ALARM unit 20. Secondary Display 10. mV/m,V/m (E) 21. BUZZER symbol 11. µA/m mA /m unit (H) 22. Decimal point 12. µW/m, µW/cm2unit anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 13: Fundamentals

    8.4 Power Density (S) Power per unit area normal to the direction of propagation, usually expressed in units of Watts per anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 14: The Characteristic Of Electromagnetic Fields

    In near-field conditions, the magnetic field value cannot be calculated from the electric field value. This meter is designed for reliable far-field measurements only. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 15: Device Operation

    • Be sure to turn unit off after use to conserve battery life. 9.2 POWER Button • Press” ”button to power on. • Press” ”button to power off. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 16: Data Hold Button

    • Computed power density (mW/m • Computed power density (µW/cm Press “ ” button to change the unit. Possible units : mV/m, V/m, µA/m , mA/m, µW/m , mW/m , µW/cm anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 17: Max / Avg Record

    ”button, the meter will save the current measured result, and REC with a number 001~200 will appear. Manual data memory storing: 200 data sets. Over load indication: “OL”. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 18: Backlight Display And Reading In The Dark

    Press and hold ” ” then press ” ” key to switch the alarm function on. The “ALARM” symbol in the display indicates that the alarm function is on. Press anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 19: Viewing Data Records

    ” key to close and exit this mode. 9.11 Clock LCD Display Press and hold the “ ” and “ ” buttons to select the display method of the Year, Month, Date, Hour and Second. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 20: Setup Mode

    • Setup 1: Clock Setup-1 • Setup 2: Setting the Alarm Limit Value (ALARM)-2 • Setup 3: Clear Data Logger Memory-3 • Setup 4: Analogue Bar Graph Setup-4 anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 21: Clock Setup-1

    ” to select the setting you want to adjust. Press “ ” button to save the setting. Date/Time default format : 2009/12/21 12:12. Year format: 2000~2099 display as 00 ~ 99. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 22: Setting The Alarm Limit Value (Alarm)-2

    Alarm limit function is only used for total three axial value. While the meter in ON, press and hold “ ” button and press “ ” button to enter Setup Mode. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 23: Del Data Logger Memory Setup-3

    While the meter in ON, press and hold the “ ” button and press “ ” button to enter Setup Mode. Press “ ” button 2 more times to enter clear data logger memory mode. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 24: Analog Bar Graph Setup-4

    X1 is normal setting. X10 is 10 times more sensitive, x100 is 100 times more sensitive. Press “ ” or “ ” to select the desired value: anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 25: Auto Power-Off Function Setup-5

    99 minutes. Set value to 00 to disable auto power-off. Press “ ” key to store the new setting value and exit. The symbol is displayed. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 26: Setting The Calibration Factor (Cal)-6

    ” to select the desired digit. Press “ “ and “ ” button to change the digit Press “ ” key to store the new setting value and exit. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 27: Calibration Factor (Cal)

    If the sensor is moved quickly, excessive field strength values could be displayed. This effect is caused by electrostatic charges. Recommendation: Hold the meter steady during the measurement. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 28: Short-Term Measurements

    Note: Use the “Average” or” Max average” modes only when the instantaneous measurement values are fluctuating greatly. You may fix the meter to a wooden or plastic tripod. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 29: Specifications

    Batteries Battery Life Approximately 15 hours Auto Power-Off Default time 15 minutes. Adjustable threshold 0~99 minutes Dimensions 60(L) x 60(W) x 195(H) mm Weight Approx. 200g (including battery) anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 30: Electrical Specifications

    ±1.0 dB (1.9 GHz to 3.5GHz) • Isotropy Deviation Typically ±1.0 dB (2.45GHz) • Overload Limit 0.42mW/cm , (11 V/m) per axis • Overload Limit (0 to 50°C): ±0.2dB anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 31: Units Of Measurement

    “MAX “symbol is displayed. Average (AVG): The digital display shows the average value measured, the “AVG” symbol is displayed. anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 32: Service, Repairs, Calibration

    Package the unit carefully using filler or bubble wrap, and if possible, ship in the original box. Ship each unit separately. (Anaheim Scientific is not responsible for any shipping damage that may occur.) anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013.
  • Page 33 • If the unit is out of warranty, prepayment is required by Check, Money Order or Credit Card. • Return all merchandise to Anaheim Scientific with pre-paid shipping. The flat-rate repair charge for Non-Warranty Service does not include return shipping.
  • Page 34: Limited Two-Year Warranty

    The warranty is void if the serial number is altered, defaced or removed. • Anaheim Scientific shall not be liable for any consequential damages, including without limitation damages resulting from loss of use. Some states do not allow limitations of incidental or consequential damages.
  • Page 35 Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...
  • Page 36 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.anaheimscientific.com © 2013 Anaheim Scientific anaheimscientific.com Technical data subject to change without notice ©Anaheim Scientific 2013. 20130719...