Master Clk Supply For Sacd Engine Fig; Check Circuits Adjacent To Q101 - Marantz SA-11S2 Service Manual

Super audio cd player
Hide thumbs Also See for SA-11S2:
Table of Contents

Advertisement

MASTER CLK SUPPLY FOR SACD ENGINE FIG

SACD Engine
(33.8688MHz)
RESET
From Front MPU
2. Check circuits adjacent to Q101 (PA16)
Display "VSTEM ERROR"
Is CLOCK (SYCL : Q101-82pin)
waveform output from both ends of R130?
no
Check Q101(XC2S15).
Is +3.3D output?
yes
Is "SYSR" (Q101-19pin) "H"?
yes
Is Q101 too hot to touch?
no
Is each part a regular one?
yes
Is any one of Q101-13pin(CX/CXON),
-43pin(SX/SXON) & -96pin(EXON)
outputting "H"? (*1)
The CLOCK is not input to each
operation mode after switching.
Check each checkup item for each
CLOCK mode.
Q101
41Pin
CD CLOCK
(33.8688MHz)
13Pin
CXON
40Pin SACD CLOCK
SYCL 82Pin
(67.7376MHz)
43Pin
SXON
81Pin
EXCLK
(67.7376MHz)
96Pin
EXON
yes
no
Check Q106's(REG.) input & output voltage
and solder points on Q102
no
Check connection between J104 and WF07.
Resolder Q101. If it is astill not improving,
yes
Some dealers alter power source, oscillator
no
and their peripheries, which are greatly
affected by timing of each clock switching.
This set is only compatible with regular
*1 : For about 300ms after the power turns on, 13pin, 43pin
and 96pin on Q101 are set to "H", and X101 based
CLOCK is supplied to mecha module.
X102
Q109
TCXO
POWER REG
768fS
(for CD)
(for CD CLK)
CD CLOCK
POWER ON/OFF
X101
Q110
X.TAL OSC
POWER REG
1536fS
(for SACD)
(for SACD CLK)
SACD CLOCK
POWER ON/OFF
X103
Q128
VCXO
POWER REG
768fS
(for EXTERNAL CLK INPUT)
(for EXTERNAL CLK)
EXT CLOCK
POWER ON/OFF
replace Q101.
specifications.
1-10
H : ON
H : ON
H : ON
Possibly caused by loose connection
between J102 and flexible cable
Check solder points on Q102
If still not improving...
Replug flexible cable

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents