Section 5: Bench Check Procedure
PROCEDURE
Actuate changer coin return lever
Manually operate each of the
changer's "Inventory"
switches until all coins are dispensed.
P.10, P.25 respectively.
Actuate the 5-10-25 inventory
control switches
If all of these procedures can be successfully completed, the changer is operating properly.
Set Coin Control Option Switches as desired. Set price(s) in vendor.
BENCH CHECK PROCEDURE
RESULT
Digital display will read ESC
Each dispensing solenoid will
energize, dispensing a coin,
digital display will read P.05,
NOTE: If lower tube sensors are
covered, the lower tube sensor LED
will illuminate, if both upper and
lower tube sensors are blocked, both
upper and lower tube sensors
LED's will illuminate.
The digital display will read
n, d, P respectively and number
of coins payed out
I.E. n 03 for 3 nickels, p 03 for
3 quarters and d 03 for 3 dimes.
FUNCTION VERIFIED
Escrow return
Manual dispense
($.05, $.10, $.25)
Pay out