Coinco CoinPro 3 Operation And Service Manual page 14

9302-gx series electronic changer
Table of Contents

Advertisement

Section 5: Bench Check Procedure
PROCEDURE
Turn tester power OFF. Remove
acceptor from changer. Block
the coin change high tube sensors
by completely filling tubes with
coins or by inserting a rolled up
tube of paper into the three coin
tubes. Replace acceptor, turn
tester power switch on and
insert (1) nickel, (1) dime and (1) quarter
Insert (1) $ coin
Insert a Canadian nickel, dime
Set changer coin
control option switches as follows:
#1: (ON) Not Used.
#2: (ON) Lo $.25 Change tube
#3: (ON) $ coin accept
Actuate changer reset switch
Insert (1) $ coin
Block the middle $.25 change tube
tube sensor without blocking the
high tube sensor by partially filling
$.25 change tube with coins
(approx. $5.00) or by inserting a
rolled up tube of paper far enough
into $.25 change tube past the high
sensor but far enough into tube to
block the middle sensor. Insert (1)
quarter.
Page 14
BENCH CHECK PROCEDURE
RESULT
Upon power up, the
digital display and tube sensors
upper and lower LED's sequence.
Coins are accepted and directed to
cash box, digital display will read
b.05, b.10, b.25 respectively and
tube sensors upper and lower
LED's will illuminate
$ coin is rejected
Coin is rejected
quarter coin switch
Digital display will read rSt
Coin is accepted and directed to
cash box, the digital display will
read b1.00
Quarter is accepted and directed to
the cash box. The digital display
will read b.25 and the upper and
lower tube sensor LED's will
illuminate
FUNCTION VERIFIED
High Tube Sensor
No $ accept switch
U.S. coins only or
Middle $.25 tube sensor

Hide quick links: