Section 5: Bench Check Procedure; Bench Check Procedure - Coinco CoinPro 3 Operation And Service Manual

9302-gx series electronic changer
Table of Contents

Advertisement

Section 5: Bench Check Procedure

BENCH CHECK PROCEDURE FOR MODEL 9302-GX
NOTE: This tester is a static sensitive device and must be used in a grounded work station.
PROCEDURE
Set changer Coin Control
Option switches as follows:
#1: (OFF) Not Used.
#2: (OFF) HI $.25 change tube.
#3: (OFF) No $ coin accept
Plug changer into tester.
Set tester power switch ON.
Set the changer Enable/Disable
switch to the Disable (down)
position and insert (1) nickel,
(1) dime and (1) quarter
Set the changer Enable/Disable
switch to the Enable (up)
position and insert (1) nickel,
(1) dime and (1) quarter
Actuate Changer Reset Switch
Randomly insert (9) nickels,
(11) dimes, and (9) quarters
Using Coinco Tester #407341
RESULT
The digital display and tube sensors
upper and lower LED's sequence, then
the display will read rSt
All coins are rejected. Digital display
reads r.05, r.10, r.25 for respective
coins when rejected
Coins are accepted, and
directed to the respective changer
coin tube, digital display will read:
t.05 when nickel is deposited
t.10 when dimes is deposited
t.25 when quarter is deposited
Digital display will read rSt
NOTE: If reset switch is held in, the
changer's communication software
revision will be displayed.(Sr2)
When the reset switch is released,
display will read rSt
Coins are accepted and directed
to changer coin tube, digital display
will read t.05, t.10, t.25 for
respective coin when the 9th, 11th &
9th coin respectively is inserted, the low
tube sensor LED will light. Example: When
the 9th nickel is accepted, the digital
display will read t.05 and the lower
tube sensor LED will illuminate.
FUNCTION VERIFIED
Power Up - Reset
Coin reject
(blocker function)
Coin accept
(accepted function)
Reset
Coin accept
Low change tube
sensors
Page 13