Delta DOP-W127B Instruction Sheet

Delta DOP-W127B Instruction Sheet

Dop-w series touch panel hmi

Advertisement

Available languages
  • EN

Available languages

Quick Links

High Color‧Wide Screen‧ User-Friendly HMI
W
DOP-
No.18, Xinglong Rd., Taoyuan City 33068,
DOP-W105B / DOP-W127B / DOP-W157B Instrunction Sheet
(1) Preface
Thank you for purchasing DELTA's DOP-W series. This instruction sheet will be helpful in the installation,
wiring and inspection of Delta HMI. Before using the product, please read this instruction sheet to ensure
correct use. You should thoroughly understand all safety precautions before proceeding with the
installation, wiring and operation. Place this instruction sheet in a safe location for future reference. Please
observe the following precautions:
Install the product in a clean and dry location free from corrosive and inflammable gases or liquids.
Ensure that all wiring instructions and recommendations are followed.
Ensure that HMI is correctly connected to a ground. The grounding method must comply with the
electrical standard of the country (Please refer to NFPA 70: National Electrical Code, 2005 Ed.).
Do not disassemble HMI, modify or remove wiring when power is applied to HMI.
Do not touch the power supply during operation. Otherwise, it may cause electric shock.
If you have any questions during operation, please contact our local distributors or Delta sales
representatives.
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or
download the most updated version at
http://www.delta.com.tw/ia

(2) Safety Precautions

Carefully note and observe the following safety precautions when receiving, inspecting, installing,
operating, maintaining and troubleshooting. The following words, DANGER, WARNING and STOP are
used to mark safety precautions when using the Delta's HMI product. Failure to observe these
precautions may void the warranty!
Installation
Comply with quick start for installation. Otherwise it may cause equipment damage.
Do not install the product in a location that is outside the stated specification for the HMI.
Failure to observe this caution may result in electric shock, fire, or explosion.
Do not install the product in a location where temperatures will exceed specification for
the HMI. Failure to observe this caution may result in abnormal operation or damage the
product.
Please note that this equipment has obtained EMC registration for commercial use. In the
event that it has been mistakenly sold or purchased, please exchange it for equipment
certified for home use.
Do not use this product as an alarm device for disaster early warning that may result in
personal injury, equipment damage, or system emergency stop.
Wiring
Connect the ground terminals to a class-3 ground (Ground resistance should not exceed
100Ω). Improper grounding may result in communication error, electric shock or fire.
Operation
The users should use Delta editing software, DOPSoft to perform editing in Delta's HMI
product. To perform editing and confirming HMI programs without using Delta editing
software, DOPSoft in Delta's HMI product may result in abnormal operation.
To prevent the personal injury and equipment damage, when designing HMI programs,
please ensure that a communication error occurred between Delta's HMI product and the
connecting controller or equipment will not result in system failure or malfunction.
Please be sure to backup the screen data and HMI programs in case they are lost,
accidentally deleted or worse.
Do not modify wiring during operation. Otherwise it may result in electric shock or
personal injury.
Never use a hard or pointed object to hit or strike the screen as doing this may damage
the screen and let the screen has not respond at all, and then cause HMI to work
abnormally.
Maintenance and Inspection
Do not touch any internal or exposed parts of the HMI as electrical shock may result.
Do not remove operation panel while power is on. Otherwise electrical shock may result.
Wait at least 10 minutes after power has been removed before touching any HMI
terminals or performing any wiring and/or inspection as an electrical charge may still
remain in the HMI with hazardous voltages even after power has been removed.
Turn the power off before changing backup battery and check system settings after
finishing change. (all data will be cleared after changing battery).
Be sure the ventilation holes are not obstructed during operation. Otherwise malfunction
may result due to bad ventilation or overheating troubles.
Wiring Method
Do not use a voltage that will exceed specification for the HMI. Failure to observe this
caution may result in electric shock or fire.
Remove the terminal block from the HMI before wiring.
Insert only one wire into one terminal on the terminal block.
If the wiring is in error, perform the wiring again with proper tools. Never use force to
remove the terminals or wires. Otherwise, it may result in malfunction or damage.

Communication Wiring

Comply with communication wiring specification for wiring.
Wiring length should comply with the stated specification for the HMI.
Proper grounding to avoid bad communication quality.
To avoid noise and interference, the communication cable, all power cables, and motor
power cable should be placed in separate conduits.
Products

(3) Pin Definition of Serial Communication

Taiwan
DOP-W105B / DOP-W127B / DOP-W157B COM2 Port
COM Port
PIN1
Note1: Blank = No Connection.
DOP-W105B / DOP-W127B / DOP-W157B COM3 Port
COM Port
PIN1
Note1: Blank = No Connection.

(4) Parts Names

DOP-W105B (Front View)
A
MODE1
MODE2
MODE3
PIN
RS-232
RS-422
RS-485
1
TXD+
D+
2
RXD
3
TXD
4
RXD+
5
SGND
SGND
SGND
6
TXD-
D-
7
RTS
8
CTS
9
RXD-
MODE1
MODE2
MODE3
PIN
RS-232
RS-422
RS-485
1
TXD+
D+
2
RXD
3
TXD
4
RXD+
5
SGND
SGND
SGND
6
TXD-
D-
7
RTS
8
CTS
9
RXD-
C
B
A
Touch Screen / Display
B
Power LED Indicator
Operation LED Indicator
C
/ Alarm LED Indicator
DOP-W105B (Rear View)
D
A
B
C
A
Power Input Terminal
B
COM2
C
COM3
D
USB Host
E
Ethernet LAN1
F
Ethernet LAN2
G
Audio
H
SD
DOP-W127B / DOP-W157B (Front View)
A
D
A
Touch Screen / Display
B
Operation LED Indicator
C
D
/ Alarm LED Indicator
E
F
G
H
D
B
C
Power LED Indicator
1.5W Built In Speaker

Advertisement

Table of Contents
loading

Summary of Contents for Delta DOP-W127B

  • Page 1 PIN1 Thank you for purchasing DELTA’s DOP-W series. This instruction sheet will be helpful in the installation, wiring and inspection of Delta HMI. Before using the product, please read this instruction sheet to ensure RXD+ correct use. You should thoroughly understand all safety precautions before proceeding with the...
  • Page 2 SDRAM 256 Mbytes 4) The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download Backup Memory 800000 numbers of data (alarm data + historical data) the most updated version at http://www.delta.com.tw/ia.
  • Page 3 DOP-W105B / DOP-127B / DOP-W157B COM3 Port (1) Önsöz MOD1 MOD2 MOD3 DELTA’nın DOP-W serisi operatör panellerini seçtiğiniz için teşekkürler. Bu bilgi dokümanı Delta HMI kurulum, bağlantı, COM Port bakım ve kontrolünde kullanıcıya yardımcı olacaktır. Doğru kullanım içins ürünü kullanmadan önce bu dokümanı mutlaka RS-232 RS-422 RS-485 okuyunuz.
  • Page 4 4-kablo rezistif dokunmatik ekran 4) Herhangi bir ihbar olmadan bu dokümanın içeriği değiştirilebilir. En son güncellenmiş halini firmamızdan talep edebilir Dokunmatik Ekran Arabirimi > 10,000,000 çalışma ya da aşağıdaki link adresinden indirebilirsiniz http://www.delta.com.tw/ia. Buzzer Multi-Tone Frekansı(2K ~ 4kHz)/80dB I2S Dekoder , Stereo I2S Dekoder , Stereo Kulaklık Girişi + Dahili 1.5W...
  • Page 5 (3) 通訊腳位定義 Ethernet LAN1 Ethernet LAN2 Audio DOP-W105B / DOP-W127B / DOP-W157B COM2 定義 MODE1 MODE2 MODE3 COM Port 示意圖 腳位 RS-232 RS-422 RS-485 DOP-W127B / DOP-W157B (正面) 高彩‧寬螢幕‧友善人機介面 DOP- TXD+ PIN1 No.18, Xinglong Rd., Taoyuan City RXD+ SGND SGND...
  • Page 6 DOP-W127B I2S Decode, Stereo I2S Decode, Stereo DOP-W157B(背面) 音效輸出 Headphone jack only Headphone jack + Built in 1.5W Speaker 1 USB Host Ver 2.0 3 USB Host Ver 2.0 302.7 +1.0 (11.92") -0.0 型號 DOP-W105B DOP-W127B DOP-W157B T=1.6mm(0.063")~6mm(0.24") SDHC X 1 59.0...
  • Page 7 (3) 通讯脚位定义 DOP-W127B / DOP-W157B (正面) DOP-W105B / DOP-W127B / DOP-W157B COM2 定义 MODE1 MODE2 MODE3 COM Port 示意图 脚位 RS-232 RS-422 RS-485 高彩‧宽屏幕‧友善人机接口 DOP- PIN1 TXD+ No.18, Xinglong Rd., Taoyuan City RXD+ 33068, Taiwan SGND SGND SGND DOP-W105B / DOP-W127B / DOP-W157B 安装说明...
  • Page 8 USB Host 重量 约 1750g 约 2830g 约 3880g (6) 硬件规格 Ethernet LAN1 Ethernet LAN2 型号 DOP-W105B DOP-W127B DOP-W157B Audio NOTE 面板种类 10.4" TFT LCD 12.1" TFT LCD 15" TFT LCD (5) 开孔尺寸 分辨率 1) 隔离电路耐受规格:可承受 1 分钟 1500V 高压突波。...

This manual is also suitable for:

Dop-w157bDop-w105b

Table of Contents