STEP 8
Wire Wallplate Terminals
NOTE: All wiring must comply with local codes
and ordinances. If unsure about household
wiring procedures, call your local heating/air
conditioning contractor.
Refer to masking tape labels you placed on
wires when you removed your old thermostat.
Match the letter of your old thermostat wire
with the terminal of the corresponding letter on
your new thermostat. Refer to figures on
pages 23 and 24 and Table 2 for typical wire
colors for easy matching.
TABLE 2—TYPICAL WIRE COLORS
AND FUNCTIONS.
Thermostat
Terminal
G
Y
W
Rc
R
a
Wire colors are typical; verify at heating/cooling
equipment connection.
In 5-wire installations only, be sure to re-
move the factory-installed jumper connect-
ing terminals R and Rc.
21
Connect to
a
Wire Color
Function
Green
Fan
Yellow
Cooling
White
Heating
Blue
Air Conditioning
Power
Red
Furnace Power
69-0733B—1